Installation Octopus II
Release 06 10/2018
Proceed as follows:
Connect the power supply cable.
Enable the supply voltage.
2.6
Connecting data cables
Note the following general recommendations for data cable connections in
environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical data cables for the data transmission between the buildings.
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances. If reducing the inductive coupling is necessary, verify
that the power supply cables and data cables cross at a 90° angle.
Use SF/UTP cables as per ISO/IEC 11801:2002.
Connect the data cables according to your requirements.
Further information:
“Ethernet ports” on page 25
2.7
Filling out the inscription label
The information field for the IP address helps you identify your device.