Hirschmann Octopus II User Manual Download Page 33

Installation Octopus II

Release 06 10/2018

33

The Terminal cable is available as an accessory.

You will find a description of the V.24 interface in the “User Manual Basic 
Configuration” document. 
 
You can find further information on the Internet on the Hirschmann product 
pages under 

www.hirschmann.com

1.8

Signal contact

The signal contact is a potential-free relay contact. The signal contact is open 
when the device is not connected to a power supply.
The signal contact allows you to control external devices or monitor device 
functions.
In the configuration, you specify how the device uses the signal contact.
You find detailed information regarding possible applications and 
configuration of the signal contact in the software user documentation on the 
Hirschmann product pages (

www.hirschmann.com

).

Summary of Contents for Octopus II

Page 1: ...Installation Octopus II Release 06 10 2018 Technical support https hirschmann support belden com User Manual Installation Managed IP65 67 Switch Octopus II...

Page 2: ...inding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschma...

Page 3: ...pply voltage with the characteristic value QQ 24 1 4 7 Supply voltage with the characteristic value PP 25 1 5 Ethernet ports 25 1 5 1 Twisted pair 25 1 5 2 Support of PoE 26 1 5 3 Optical fiber 28 1 5...

Page 4: ...ge with the characteristic value N9 39 2 4 6 Supply voltage with the characteristic value QQ 41 2 4 7 Supply voltage with the characteristic value PP 41 2 4 8 Signal contact 43 2 5 Operating the devic...

Page 5: ...ell as practical knowledge and experience make up their qualifications This is the prerequisite for grounding and labeling circuits devices and systems in accordance with current standards in safety t...

Page 6: ...application case Table 1 Requirements for connecting electrical wires All of the following requirements are complied with The voltage connected complies with the requirements for a safety extra low v...

Page 7: ...copper Exclusively for device variants featuring supply voltage with characteristic value BB FF HH QQ The power supply cable is suitable for the voltage the current and the physical load Hirschmann re...

Page 8: ...wer supply cable is suitable for the voltage the current and the physical load Hirschmann recommends a wire diameter of 0 5 mm to 0 75 mm AWG20 up to AWG18 Exclusively for device variants featuring su...

Page 9: ...ct the grounding only after disconnecting all other cables Use toothed washers to ensure good electrical conductivity at the connection Device casing Only technicians authorized by the manufacturer ar...

Page 10: ...654 Neckartenzlingen Germany www hirschmann com The product can be used in the industrial sector Interference immunity EN 61000 6 2 Emitted interference EN 55032 Reliability EN 60950 1 You find more i...

Page 11: ...ing interference that may cause undesired operation Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulatio...

Page 12: ...iption safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the Installation user manual that is not supplied with...

Page 13: ...Installation Octopus II Release 06 10 2018 13 Key The symbols used in this manual have the following meanings Listing Work step Subheading...

Page 14: ...t a fan The redundancy concept allows the network to be reconfigured quickly There are convenient options for managing the device Manage your devices via Web browser SSH Telnet V 24 interface locally...

Page 15: ...T5 10 100 Mbit s twisted pair port 4 pin D coded M12 socket R5 10 100 Mbit s twisted pair port 4 pin D coded M12 socket with bypass relay T6 10 100 1000 Mbit s twisted pair port 8 pin X coded M12 sock...

Page 16: ...d voltage range 72 V DC 110 V DC Connection type 4 pin 7 8 connector QQ 2 voltage inputs for redundant power supply Rated voltage range 24 V DC 48 V DC Connection type 4 pin T coded M12 power plug PP...

Page 17: ...Software configuration E Entry without configuration D DLR P ProfiNET IO I Ethernet IP B BDEW 30 31 Software level 2S HiOS Layer 2 Standard 2A HiOS Layer 2 Advanced 3S HiOS Layer 3 Standard 32 36 Soft...

Page 18: ...X X X X X EN 60950 1 X X X X X X X X X X X EN 61131 2 X X X X X X X X X X X FCC X X X X X X X X X X X cUL 60950 1 X X X X X X Navy applications DNV GL X X X X Railway applications trackside EN 50121...

Page 19: ...A 1B 1C 1D 4M 4S 4P 4L 4A 4B 4C 4D 5M 5S 5P 5L 5A 5B 5C 5D 1000 Mbit s F O port M SFP SX LC EEC V1 X V4 X QODC X M SFP LX LC EEC V1 X V4 X QODC X M SFP LH LC EEC V1 X V4 X QODC X M SFP LH LC EEC V1 X...

Page 20: ...LC EEC V1 X V4 X QODC X Explanation V1 IP67 plug as per IEC 61076 3 106 variant 1 V4 IP67 connector as per IEC 61076 3 106 variant 4 Q ODC HUBER SUHNER Port type Built in transceivers Version Charact...

Page 21: ...ting 2 LED display elements for device status Table 10 Description of the device view 5 7 6 8 V 24 ACA P IP ADDRESS Produktcode 1 ACA Power RM Status 2 3 4 1 3 2 4 5 6 7 8 9 10 11 9 11 10 12 13 14 15...

Page 22: ...e with characteristic value QQ 4 pin T coded M12 power plug Supply voltage with the characteristic value PP 4 pin T coded M12 power plug 6 Uplink ports 3 and 4 6a Twisted pair ports are located on the...

Page 23: ...ristic value 2 100 Mbit s F O port Version See table 8 on page 19 Alternatively Data rate characteristic value 3 1000 Mbit s F O port Version See table 8 on page 19 8 alternatively depending on device...

Page 24: ...undant supply to the device Further information Supply voltage with the characteristic value HH on page 38 1 4 4 Supply voltage with the characteristic value M9 A 3 pin 7 8 plug is available for the p...

Page 25: ...de optical fiber Singlemode optical fiber Twisted pair cable You find information on pin assignments for making patch cables here Pin assignments on page 29 1 5 1 Twisted pair 10 100 Mbit s twisted pa...

Page 26: ...cted with the device housing 1 5 2 Support of PoE The device variants featuring hardware type characteristic value 4 support Power over Ethernet PoE and Power over Ethernet Plus PoE With the presence...

Page 27: ...ing to standards IEEE 802 3 10BASE T 100BASE TX and IEEE 802 3af at 10 100 1000 Mbit s PoE port The 10 100 1000 Mbit s PoE port allows you to connect network components as a powered device PD accordin...

Page 28: ...according to the IEEE 802 3 100BASE FX standard This port supports Full duplex mode 1000 Mbit s F O port The 1000 Mbit s F O port offers you the ability to connect network components according to the...

Page 29: ...ata PoE 1 TX Positive VPSE 2 RX Negative VPSE 3 TX Positive VPSE 4 RX Negative VPSE M12 8 pin X coded Pin 10 100 Mbit s 1000 Mbit s PoE 1 RX BI_DB Negative VPSE 2 RX BI_DB Negative VPSE 3 TX BI_DA Pos...

Page 30: ...A21 M12 ACA22 M12 storage medium USB interface none ACA storage medium not connected green lights up ACA storage medium connected flashes3 times a period Device writes to reads from the storage medium...

Page 31: ...2 storage medium You can obtain this as accessory See Accessories on page 62 LED Display Color Activity Meaning L D Link status none Device detects an invalid or missing link green lights up Device de...

Page 32: ...stem monitor The socket housing is electrically connected to the housing of the device Figure 1 Terminal cable for connecting an external Management Station Pin Function 1 Uin 5 V 2 N C Not used 3 D D...

Page 33: ...1 8 Signal contact The signal contact is a potential free relay contact The signal contact is open when the device is not connected to a power supply The signal contact allows you to control external...

Page 34: ...cription label Making basic settings 2 1 Checking the package contents Proceed as follows Check whether the package includes all items named in the section Scope of delivery on page 60 Check the indiv...

Page 35: ...the device on a level surface with 4 M5 screws To preserve the suitability of your device for IP65 67 proceed as follows Remove the provided transport protection caps and the transport protection scre...

Page 36: ...t max distance 19 7 in 50 cm Lock the ferrite 2 4 Connecting the power supply and the signal contact lines 2 4 1 Supply voltage with the characteristic value BB A 5 pin M12 plug is available for the r...

Page 37: ...figuration in the Management Connect the electrical wires to the socket according to the pin assignment Type and specification of the supply voltage Pin assignment Rated voltage 24 V DC 1 Plus termina...

Page 38: ...2 4 3 Supply voltage with the characteristic value HH A 5 pin M12 plug is available for the redundant supply to the device You find the prescribed tightening torque in chapter See Technical data on pa...

Page 39: ...vailable for the power supply to the device You find the prescribed tightening torque in chapter See Technical data on page 49 The supply voltage is connected to the device casing through protective e...

Page 40: ...socket according to the pin assignment Type and specification of the supply voltage Pin assignment Rated voltage 72 V DC 110 V DC N C Voltage range incl maximum tolerances 50 4 V DC 138 V DC P Plus t...

Page 41: ...e the device reports the loss of a supply voltage You can prevent this message by changing the configuration in the Management Connect the electrical wires to the socket according to the pin assignmen...

Page 42: ...ment Connect the electrical wires to the socket according to the pin assignment Type and specification of the supply voltage Pin assignment when using PoE Rated voltage 48 V DC Voltage range incl maxi...

Page 43: ...c value HH Pin assignments for device variants Supply voltage with characteristic value FF Supply voltage with the characteristic value M9 Supply voltage with the characteristic value N9 Supply voltag...

Page 44: ...opper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables d...

Page 45: ...protocol in the applications HiDiscovery or Industrial HiVision Configuration via BOOTP Configuration via DHCP Option 82 AutoConfiguration Adapter Default settings IP address The device looks for the...

Page 46: ...cm from the device It depends on the installation conditions of the device for example the distance from other devices or other objects and the output of neighboring devices The temperature displayed...

Page 47: ...cy of the switching operations Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working on...

Page 48: ...e Disconnect the data cables Disconnect the power supply cables and signal lines Disconnect the grounding WARNING ELECTRIC SHOCK Disconnect the grounding only after disconnecting all other cables Fail...

Page 49: ...upply voltage with the characteristic value HH Rated voltage range 36 V DC 48 V DC Voltage range incl maximum tolerances 25 2 V DC 60 V DC Connection type 5 pin M12 connector Tightening torque 5 3 lb...

Page 50: ...oE power 60 W Connection type 3 pin 7 8 connector Tightening torque 22 lb in 2 5 Nm Power loss buffer 10 ms at 93 5 V AC Overload current protection at input Non replaceable fuse Back up fuse OS20 OS3...

Page 51: ...re characteristic value T extended 40 F 158 F 40 C 70 C Deratinga Exclusively for device variants featuring temperature range characteristic value T Mount the device on a 1 62 sq ft 0 15 m large 0 09...

Page 52: ...e of 2 in 5 cm from the device d Exception Device variants with supply voltage characteristic value PP e Remove the provided transport protection caps and the transport protection screws from the devi...

Page 53: ...n Octopus II Release 06 10 2018 53 Dimension drawings 338 2 13 31 186 7 32 150 5 91 120 4 72 326 2 12 84 308 8 12 16 1 85 47 39 3 0 15 39 4 0 16 39 3 0 15 261 10 28 249 9 8 94 8 3 73 92 7 3 65 10 9 0...

Page 54: ...stallation Octopus II Release 06 10 2018 EMC and immunity Note You will find detailed information on the certificates and declarations applying to your device in a separate overview See table 7 on pag...

Page 55: ...A Class A EN 61000 6 4 Fulfilled Fulfilled Fulfilled Fulfilled Fulfilled Conducted emission EN 55032 DC supply connection Class A Class A Class A Class A Class A DNV GL Guidelines DC supply connection...

Page 56: ...ield EN 61000 4 3 80 MHz 3000 MHz max 10 V m max 10 V m max 20 V m max 20 V m max 10 V m Fast transients burst EN 61000 4 4 IEEE C37 90 1 DC supply connection 2 kV 2 kV 2 kV 2 kV 2 kV EN 61000 4 4 IEE...

Page 57: ...t Fc Vibration 5 Hz 8 4 Hz with 0 14 in 3 5 mm amplitude 2 Hz 13 2 Hz with 0 04 in 1 mm amplitude Operating 5 Hz 150 Hz Broadband noise vertical 1 0 m s rms horizontal 0 7 m s rms 8 4 Hz 150 Hz with 1...

Page 58: ...dB 0 mi 2 49 mi 0 km 4 km 1 0 dB km 500 MHz km SM LC SM 1310 nm 9 125 m 0 dB 12 dB 0 mi 13 98 mi 0 km 22 5 km 0 4 dB km 3 5 ps nm km SM LC SM 1310 nm 9 125 m 10 dB 28 dB 15 53 mi 38 84 mi 25 km 62 5...

Page 59: ...Singlemode Longhaul b Including 3 dB system reserve when compliance with the fiber data is observed c Using the bandwidth length product is inappropriate for expansion calculations 10 100 1000 Mbit s...

Page 60: ...0 including 60 W PoE output power 106 W 149 Btu IT h OS24 xx2800 including 60 W PoE output power 108 W 157 Btu IT h OS30 0008xx 26 W 87 Btu IT h OS30 0016xx 27 W 94 Btu IT h OS30 0024xx 29 W 100 Btu I...

Page 61: ...connector 1 Only for device variants featuring supply voltage with characteristic value N9 7 8 connectors 4 pin Design HH Hirschmann Standard HA Hirschmann with angled connector 1 Only for device var...

Page 62: ...ed 942 218 001 M12 connector 4 pin D coded 934 445 001 7 8 connector 3 pin 942 086 003 7 8 connectors 4 pin 942 086 004 7 8 connectors 5 pin 942 086 005 Protection screw for M12 socket metal IP65 67 2...

Page 63: ...Generic standards Emitted interference in industrial environments EN 60950 1 Information technology equipment Safety Part 1 General requirements CSA 22 2 No 60950 1 Information Technology Equipment S...

Page 64: ...Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through netw...

Page 65: ...Installation Octopus II Release 06 10 2018 65...