![Hirschmann Octopus II User Manual Download Page 42](http://html1.mh-extra.com/html/hirschmann/octopus-ii/octopus-ii_user-manual_2138111042.webp)
42
Installation Octopus II
Release 06 10/2018
The supply voltage is connected to the device casing through protective
elements exclusively.
You have the option of supplying the supply voltage redundantly, without
load distribution.
With a non-redundant supply of the supply voltage, the device reports the
loss of a supply voltage. You can prevent this message by changing the
configuration in the Management.
Connect the electrical wires to the socket according to the pin
assignment.
Type and specification of the
supply voltage
Pin assignment
when using PoE:
Rated voltage
48 V DC
Voltage range incl. maximum
tolerances
47 V DC ... 57 V DC
when using PoE+:
Rated voltage
54 V DC
Voltage range incl. maximum
tolerances
53 V DC ... 57 V DC
without using PoE or PoE+:
Rated voltage range
24 V DC ... 48 V DC
Voltage range incl. maximum
tolerances
19 V DC ... 60 V DC
P1+
Plus terminal of supply
voltage 1
P1
−
Minus terminal of supply
voltage 1
P2+
Plus terminal of supply
voltage 2
P2
−
Minus terminal of supply
voltage 2
P2
-
P1+
P2+
P1
-