2.6
Connecting the supply voltage,
starting up
Ground the device before connecting the power supply.
Only connect plugs and other components that fulfill protection class
IP65/67 and that are certified for the required temperature range.
Use a back-up fuse suitable for the supply network.
See “General technical data” on page 33.
Make sure that the disconnecting device is easily accessible for
disconnecting the device from the mains voltage.
Note:
Connectors are not electrical isolating devices. Therefore, first plug the
connector into the power supply plug and then switch on the power supply.
Connect the power supply connector to the power supply socket of the
device.
Note:
For the supply voltage on the input, use a wire cross section of at
least 1 mm² (North America: AWG16).
When you connect the supply voltage, you start up the device.
Figure
Pin
Function
1
+ 48 V DC (1)
2
Fault
3
0 V DC
4
+ 48 V DC (2)
5
Fault
Table 8:
Pin assignment of the 5-pin M12 socket for connecting the PoE supply
voltage and the signal contact