Installation OCTOPUS 8M/16M/24M/OS32

Release 11 01/2013

33

7

Technical data

General technical data

Dimensions 
W × D × H

OCTOPUS 8M...
OCTOPUS 16M...,
OCTOPUS OS32-0808...
OCTOPUS 24M...,
OCTOPUS OS32-0816...

184 × 189 × 70 mm

261 × 189 × 70 mm

338 × 189 × 70 mm

Weight

OCTOPUS 8M
OCTOPUS 8M-Train
OCTOPUS 8M-Train-BP
OCTOPUS 8M-8PoE
OCTOPUS 8M-6PoE

approx. 1.3 kg

OCTOPUS 16M
OCTOPUS 16M-Train
OCTOPUS 16M-Train-BP
OCTOPUS 16M-8PoE

approx. 1.9 kg

OCTOPUS OS32-0808...

approx. 1.0 kg

OCTOPUS 24M
OCTOPUS 24M-Train
OCTOPUS 24M-Train-BP
OCTOPUS 24M-8PoE

approx. 1.5 kg

OCTOPUS OS32-0816...

approx. 1.7 kg

Power supply
OCTOPUS... (without 
PoE)

Redundant power supply
Safety extra-low voltage (SELV/PELV) redundant inputs disconnected.
Relevant for North America: Nec Class 2 power source max. 2 A.
Rated voltage range DC

24 V ... 48 V

Voltage range DC incl. maximum 
tolerances

9,6 V ... 60 V

Connection type

M12 connector, 5-pin

Power failure bypass

> 10 ms

Back-up fuse

Nominal rating: 
Characteristic:

5 A
slow blow

Peak inrush current

13,8 A

Power supply
OCTOPUS...PoE... 
und OS32-... 

Redundant power supply
Safety extra-low voltage (SELV/PELV) redundant inputs disconnected.
Max. 5 A
Nominal voltage DC:

48 V

Voltage range DC incl. maximum 
tolerances

46 V ... 57 V

Connection type

M12 connector, 5-pin

Power failure bypass

> 10 ms
when using a PC150... power supply 
unit

Back-up fuse

Nominal rating: 
Characteristic:

5 A
slow blow

Peak inrush current

14 A

Summary of Contents for OCTOPUS 8M Series

Page 1: ...16 17 18 1 2 P1 P2 RM FAULT V 24 ACA Power 1 2 P Managed ETHERNET Switch x y OCTOPUS OS32 Produktcode IP ADDRESS Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 1 2 3 4 5 48V DC 48V DC Function Pin 1 2 3 4...

Page 2: ...res described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the comp...

Page 3: ...d pair connection for PoE 4 pin M12 sockets 15 1 5 3 10 100 1000 Mbit s twisted pair connection 8 pin M12 connector X coded 16 1 5 4 100 1000 Mbit s FO connection SFP IP67 V1 connector based on IEC 61...

Page 4: ...6 Connecting the supply voltage starting up 26 2 7 Connecting the data lines 27 3 Basic set up 28 4 Monitoring the ambient air temperature 30 5 Maintenance and service 31 6 Disassembling the SFP trans...

Page 5: ...angled cable socket Relevant for North America Devices without Power over Ethernet PoE may only be connected to a supply voltage of class 2 that fulfills the requirements of the National Electrical C...

Page 6: ...requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and operation of this product and are app...

Page 7: ...y only be carried out by personnel trained for this purpose Relevant for OCTOPUS OS32 08xx02O6O6 Note LED or LASER components in compliance with IEC 60825 1 2007 CLASS 1 LASER PRODUCT CLASS 1 LED PROD...

Page 8: ...compatibility In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Con...

Page 9: ...ons These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can a...

Page 10: ...ndancy Configuration user manual Reference manual for the graphical user interface Command Line Interface user manual The Industrial HiVision Network Management Software provides you with additional o...

Page 11: ...d pair cable multimode F O singlemode F O There are convenient options for managing the device Administer your devices via Telnet a Web browser management software such as Industrial HiVision a V 24 i...

Page 12: ...P OCTOPUS 16M Train BP OCTOPUS 24M Train BP As long as the device is switched off and during the system start relays connect port 4 and port 8 to each other on a crossed basis This passive bypass enab...

Page 13: ...the OCTOPUS PoE and OS32 provides six to eight 10BASE T 100BASE TX ports M12 sockets for connecting network segments or PoE terminal devices PD Powered Device for all IEEE802 3af classes up to a maxi...

Page 14: ...ice only with the higher output voltage The supply voltage is electrically isolated from the housing With non redundant supply of the mains voltage the device reports a power failure You can avoid thi...

Page 15: ...twisted pair connection for PoE 4 pin M12 sockets 10 100 Mbit s TP PoE ports enable the connection of terminal devices or independent network segments according to the IEEE 802 3 10BASE T 100BASE TX...

Page 16: ...sing is electrically connected to the device housing Figure Pin Function PoE PSE 1 TX Transmit Data 2 RX Receive Data 3 TX Transmit Data 4 RX Receive Data Housing shield Table 2 Pin assignment of the...

Page 17: ...transceiver M Fast SFP SM LC EEC Patch cables Wire pairs M12 4 pin on M12 4 pin crossed MDI to MDI 1 TX 2 RX 2 RX 1 TX 3 TX 4 RX 4 RX 3 TX M12 4 pin on M12 4 pin 1 1 MDI to MDI X via auto crossing por...

Page 18: ...also reported in RM mode Ring redundancy reserve is available On delivery there is no ring redundancy monitoring You can also use the Management to set the signal contact manually and thus control ex...

Page 19: ...face uses the housing potential and for devices without PoE it uses the supply voltage potential Figure 1 Terminal cable for connecting an external Management Station You will find a description of th...

Page 20: ...d error display is independent of the setting of the signal contact LED Display Color Activity Meaning P1 Supply voltage 1 Green Lights up The supply voltage is on None The supply voltage is too low P...

Page 21: ...port status for activated Power over Ethernet via the software management LED Display Color Activity Meaning Port No Link status None The device detects an invalid or missing connection Green Lights...

Page 22: ...fire protection is only achieved under the following conditions All the unused connections and ports are closed with locking screws All the connectors and cables connected also fulfill protection cla...

Page 23: ...r for supply voltage and signal contact Note The permitted cable diameter for connector ELWIKA 5012 PG7 is 4 mm to 6 mm To ensure the watertightness of the OCTOPUS 8M 16M 24M OS32 device only use volt...

Page 24: ...d ports with the protection caps available as accessories See Accessories on page 42 Install the device in a location where the climatic threshold values specified in the technical data are adhered to...

Page 25: ...ccording to IEEE 802 3af insulation resistance 48 V output to rest of the world 2250 V DC for 1 min Output power 150 W Current limitation 5 A Power supply unit and PoE media module form a limited powe...

Page 26: ...y accessible for disconnecting the device from the mains voltage Note Connectors are not electrical isolating devices Therefore first plug the connector into the power supply plug and then switch on t...

Page 27: ...ons are located in the interior of the building and are specified as SELV circuits Note Applies for the device variants OCTOPUS Train BP For coupling using relay ports the maximum permitted overall le...

Page 28: ...y ports Deactivate the Spanning Tree Protocol if you use the relay ports as data rate 10 Mbits s Use the same port configuration for the relay ports The device features the following options Auto nego...

Page 29: ...public read only Login admin password private read and write Parameters that can be set via the management are set to pre defined values in accordance with the MIB V 24 data rate 9 600 Baud Ring redun...

Page 30: ...f 5 cm from the device It depends on the installation conditions of the device e g the distance from other devices or other objects and the output of neighboring devices The temperature displayed in t...

Page 31: ...Operate this device according to the specifications see Technical data Hirschmann is continually working to improve and develop our software You should regularly check whether there is a new version...

Page 32: ...ee fig 4 Figure 4 SFP mounting tool 1 mounting side 2 barbed hooks 3 disassembly side Insert the SFP mounting tool into the SFP transceiver so that the barbed hooks point to the base plate of the devi...

Page 33: ...without PoE Redundant power supply Safety extra low voltage SELV PELV redundant inputs disconnected Relevant for North America Nec Class 2 power source max 2 A Rated voltage range DC 24 V 48 V Voltage...

Page 34: ...ng current max 1 A ohmic load Switching voltage max 60 V DC or max 30 V AC SELV Climatic conditions during operation Ambient temperature 40 F 158 F 40 C 70 C Humidity 10 100 condensing Air pressure mi...

Page 35: ...OCTOPUS 8M 16M 24M OS32 Release 11 01 2013 35 Dimension drawings Figure 6 Measurements for the following devices OCTOPUS 8M shown in the figure OCTOPUS 8M Train OCTOPUS 8M Train BP OCTOPUS 8M 6PoE OCT...

Page 36: ...elease 11 01 2013 Figure 7 Dimensions for the following devices OCTOPUS 16M shown in the figure OCTOPUS 16M Train OCTOPUS 16M Train BP OCTOPUS 16M 8PoE OCTOPUS OS32 080802T6T6TPEPHH OCTOPUS OS32 08080...

Page 37: ...M 24M OS32 Release 11 01 2013 37 Figure 8 Dimensions for the following devices OCTOPUS 24M shown in the figure OCTOPUS 24M 8PoE OCTOPUS 24M Train OCTOPUS 24M Train BP OCTOPUS OS32 081602T6T6TPEPHH OCT...

Page 38: ...OCTOPUS Train 300 A m EMC interference emission EN 55022 Class A Yes FCC 47 CFR Part 15 Class A Yes German Lloyd Classification Construction Guidelines VI 7 3 Part 1 Ed 2001 only for the OCTOPUS 8M O...

Page 39: ...h ultra low loss optical fiber 18 ps nm km Table 9 Fiber port 100BASE FX SFP fiber optic Fast Ethernet Transceiver Product code M SFP Wave length Fiber System attenua tion Example for F O line length...

Page 40: ...Class0 PD 13 5 W 145 0 W 46 Btu IT h 62 Btu IT h OCTOPUS 24M 13 5 W 46 Btu IT h OCTOPUS 24M Train 13 5 W 46 Btu IT h OCTOPUS 24M Train BP 14 0 W 48 Btu IT h OCTOPUS 24M 8PoE non PD powered device 8 Cl...

Page 41: ...HH OCTOPUS OS32 080802T6T6TPEPHH OCTOPUS OS32 081602O6O6TPEPHH OCTOPUS OS32 080802O6O6TPEPHH OCTOPUS OS32 080802O6O6TPEPH1 Octopus device Connector ELWIKA 5012 PG7 for supply voltage and signal contac...

Page 42: ...WIKA 5012 PG7 5 pin M12 socket for supply voltage and signal contact 933 175 100 Field attachable 5 pin M12 socket A coded with 2 cable outputs RKC5 Duo M12 connector 4 pin D coded 934 445 001 M12 con...

Page 43: ...C to 70 C 943 898 001 Name UL 508 Safety for Industrial Control Equipment EN 50121 4 Railway applications EMC emitted interference and interference immunity for signal and telecommunication systems EN...

Page 44: ...44 Installation OCTOPUS 8M 16M 24M OS32 Release 11 01 2013...

Page 45: ...54 9860 E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluatio...

Page 46: ......

Reviews: