![Hirschmann MACH4000 Series User Manual Download Page 7](http://html1.mh-extra.com/html/hirschmann/mach4000-series/mach4000-series_user-manual_2138101007.webp)
Installation MACH4000
Release 14 06/2013
7
The basic board must not be removed.
Removing the basic board invalidates the guarantee.
The chassis should be installed in the horizontal position.
After the device is switched off, the fan blades continue rotating for a
number of seconds. Do not reach into a rotating fan!
The internal workings of the basic device are not for users! Do not
reach inside a switched-on device because of the danger caused by
high energy densities.
When fully equipped with media modules, the device weighs up to 10
kg. Please comply with the legally stipulated maximum weight when
dealing with heavy objects.
If you are operating the device in a 19" switch cabinet: install
sliding/mounting rails for supporting the weight of the device.
See “Mounting in a switch cabinet” on page 40.
Environment
Only operate the device at the specified ambient temperature
(temperature of the ambient air at a distance of up to 5 cm from the
device) and at the specified relative humidity.
Select the assembly location such that climatic limit values specified in
the technical data are maintained.
Only to be used in an environment with the pollution degree specified
in the technical data.
Increased ambient temperature: When you are operating the device in
a closed switch cabinet or together with other devices in a switch
cabinet, the ambient temperature in the switch cabinet can be higher
than the ambient temperature in the room. Only install the device in an
ambient temperature in line with the maximum ambient temperature
specified by the manufacturer: t
max
.
Mechanical stress: Install the device in a switch cabinet in such a way
that rules out hazardous conditions due to severe mechanical stress.
Qualification requirements for personnel
Qualified personnel as understood in this manual and the warning signs,
are persons who are familiar with the setup, assembly, startup, and
operation of this product and are appropriately qualified for their job. This
includes, for example, those persons who have been:
trained or directed or authorized to switch on and off, to ground and to
label power circuits and devices or systems in accordance with current
safety engineering standards;
trained or directed in the care and use of appropriate safety equipment
in accordance with the current standards of safety engineering;
trained in providing first aid.
Summary of Contents for MACH4000 Series
Page 66: ...66 Installation MACH4000 Release 14 06 2013...
Page 67: ...67 Installation MACH4000 Release 14 06 2013...
Page 68: ......