![Hirschmann MACH4000 Series User Manual Download Page 33](http://html1.mh-extra.com/html/hirschmann/mach4000-series/mach4000-series_user-manual_2138101033.webp)
Installation MACH4000
Release 14 06/2013
33
LED
Display
Color
Activity
Meaning
P
Power
supply
Green
Lights up
The supply voltage is on.
None
The supply voltage is too low.
LED
Display
Color
Activity
Meaning
P1
Power
supply
Green
Lights up
Supply voltage 1 is present at the plug-in
power unit.
None
No supply voltage 1, or voltage too low, at
the plug-in power unit.
Green
flashing
Supply voltage 1 is present, but the plug-in
power unit is reporting an error.
LED
Display
Color
Activity
Meaning
P2
Power
supply
Green
Lights up
Supply voltage 2 is present at the plug-in
power unit.
None
No supply voltage 2, or voltage too low, at
the plug-in power unit.
Green
flashing
Supply voltage 2 is present, but the plug-in
power unit is reporting an error.
LED
Display
Color
Activity
Meaning
P3
Power
supply
Green
Lights up
Supply voltage 3 is present at external input
3.
None
No supply voltage 3, or voltage too low, at
external input 3
Green
flashing
Supply voltage 3 is present, but the plug-in
power unit is reporting an error.
LED
Display
Color
Activity
Meaning
P4
Power
supply
Green
Lights up
Supply voltage 4 is present at external input
4.
None
No supply voltage 4, or voltage too low, at
external input 4
Green
flashing
Supply voltage 4 is present, but the plug-in
power unit is reporting an error.
LED
Display
Color
Activity
Meaning
RM
Ring
Manager
Green
Lights up
The RM function is active.
The redundant port is disabled.
Yellow
Lights up
The RM function is active.
The redundant port is enabled.
None
The RM function is deactivated.
Green
flashing
The device detects an incorrect configuration
of the HIPER-Ring (e.g. the ring is not
connected to the ring port).
LED
Display
Color
Activity
Meaning
RL1
Signal
contact
(Relay 1)
Red
Lights up
Signal contact 1 is open; it is reporting an
error.
Yellow
Lights up
Signal contact 1 is open.
The “Manual setting” is active.
None
Signal contact 1 is closed, it is
not
reporting
an error, or it was closed via the “Manual
setting”.