Technical data
General technical data
Dimensions
MACH4002-...
M4-POWER
W x H x D: 480 mm × 88 mm × 435 mm
W x H x D: 480 mm × 88 mm × 435 mm
Assembly
MACH4002-...
M4-POWER
19" switch cabinet
19" switch cabinet
Weight
MACH4002-...
7.5 kg
Power supply
MACH4002-...
M4-S-xx power supply unit or power unit chassis
M4-POWER with M4-P-xx power supply unit
please order separately
Operating voltage M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
Nominal voltage AC: 100 ... 240 V, 50 ... 60 Hz
Voltage range AC: 90 ... 265 V, 47 ... 63 Hz
24 V DC (19.2 V ... 32 V)
a
48 V DC (38.4 V ... 60 V)
a
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
Nominal voltage AC: 100 ... 240 V, 50 ... 60 Hz
Voltage range AC: 90 ... 265 V, 47 ... 63 Hz
24 V DC (19.2 V ... 32 V)
a
48 V DC (38.4 V ... 60 V)
a
Buffer time
M4-P-AC/DC 300W
M4-...-24VDC 300W
M4-...-48VDC 300W
min. 1/2 mains period
min. 10 ms at 20.4 V DC
min. 10 ms at 40.8 V DC
Current
consumption
M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
max. 1.7 A (240 V AC), max. 4.0 A (100 V AC)
max. 16.0 A (24 V DC), max. 20.0 A
(19.2 ... 32 V DC)
max. 8.0 A (48 V DC), max. 10 A
(38.4 ... 60 V DC)
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
max. 1.7 A (240 V AC), max. 4.0 A (100 V AC)
max. 16.0 A (24 V DC), max. 20.0 A
(19.2 ... 32 V DC)
max. 8.0 A (48 V DC), max. 10.0 A
(38.4 ... 60 V DC)
Activation current
M4-S-AC/DC 300W
M4-P-AC/DC 300W
typ. <40.0 A at 265 V AC and cold start
typ. <40.0 A at 265 V AC and cold start
Overload current
protection at input
Non-replaceable fuse
Potential difference
between incoming
voltage and
housing
M4-...-...VDC 300W
Potential difference from incoming voltage
+24 V DC/ +48 V DC: 60 V DC
Potential difference from incoming voltage 0 V:
60 V DC
b
“FAULT” signal
contact
Switching current
Switching voltage
Insulation voltage
max. 1 A, SELV
max. 60 V DC or max. 30 V AC, SELV
to front panel, power supply, other inputs/outputs:
max. 1,500 V DC
Environment
Storage temperature
Humidity
Air pressure
Ambient air: -25 °C ... +70 °C
10 % ... 95 % (non condensing)
Up to 2000 m (795 hPa), higher altitudes on request