58
Installation MACH4000
Release 14 06/2013
EMC and immunity
Network range
EMC interference
immunity
IEC/EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
IEC/EN 61000-4-3
Electromagnetic field
80 - 2,700 MHz
10 V/m
IEC/EN 61000-4-4
Fast transients (burst)
- Power line
- Data line
2 kV
4 kV
IEC/EN 61000-4-5
Voltage surges
- Power line, line/line:
- Power line, line/earth
- Data line
2 kV
2 kV
4 kV
IEC/EN 61000-4-6
Line-conducted interference voltages
150 kHz - 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300
A/m
EMC interference
emission
EN 55022
Class A
Yes
FCC 47 CFR Part 15 Class A
Yes
German Lloyd
Classifi Construction Guidelines VI-7-3 Part 1 Ed.2001 Yes
Stability
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2
Yes
Germanischer Lloyd Guidelines for the Performance of Type
Tests Part 1
Yes
Shock
IEC 60068-2-27 Test Ea test level according to IEC 61131-2
Yes
TP port
Length of a twisted pair segment
max. 100 m (cat5e cable with 1000BASE-T)
Table 9:
TP port 10BASE-T / 100BASE-TX / 1000BASE-T
Product
code
M-FAST-
SFP-...
Wave
length
Fiber
System
attenuatio
n
Example
for F/O
line length
Fiber data BLP/
dispersion
-MM/LC... MM 1310 nm 50/125 µm
0-8 dB
0-5 km
1.0 dB/km
800 MHz×km
-MM/LC... MM 1310 nm 62.5/125 µm 0-11 dB
0-4 km
1.0 dB/km
500 MHz×km
-SM/LC... SM 1310 nm 9/125 µm
0-13 dB
0-25 km
0.4 dB/km
3.5 ps/(nm×km)
Table 10: Fiber port 100BASE-FX (SFP fiber optic Fast Ethernet Transceiver)