Troubleshooting
© 2008 HIRSCHMANN Automation and Control GmbH · Branch Office Ettlingen · eMail: [email protected] · www.hirschmann-usa.com
46
50 650 19 0201e_Rev C (LinkBelt278).doc / 2008-08-18 / Rev. C / rk
7.2
LMI System Malfunction Table (LMLG V 1.x)
Fault
code
Error
Cause
Elimination
E01
Lowered below radius
range or angle range
exceeded
•
Fallen below the minimum
radius or gone past the maxi-
mum angle specified in the re-
spective load chart due to rais-
ing the boom too far
•
Lower the boom to a ra-
dius or angle specified in
the load chart.
E02
Radius range ex-
ceeded or lowered
below angle range
•
Gone past the maximum radius
or lowered below the minimum
angle specified in the respec-
tive load chart due to lowering
the boom too far
•
Raise the boom to a radius
or angle specified in the
load chart.
•
A non existing operating mode
has been selected
•
Set the correct operating
mode for the operating state
in question
•
The boom is in a non-permitted
slewing zone
•
Slew the boom to a permit-
ted area.
E04
Operating mode not
acknowledged or non
permitted slewing zone
•
The selected operating mode is
not available in the Flash-
EPROM or blocked
•
Check the Data software in
the Flash-EPROM
•
A non existing main boom
length has been selected
•
Set the correct main boom
length for the operating
state in question
E05
Main boom length not
available
•
The selected main boom length
is not available in the Flash-
EPROM or blocked
•
Check the Data software in
the Flash-EPROM
E06
Radius range ex-
ceeded or lowered
below angle range with
luffing jib operation
•
Maximum radius as specified in
the load chart exceeded or low-
ered below minimum angle due
to lowering the luffing jib too far
•
Raise the jib to a radius or
angle specified in the load
chart.
E07
Overload relays check
•
Relays = overload active and
CU input 20 = on
•
Relays = no overload and CU
input 20 = off
•
Check cable to overload
relays and CU input 20
•
Check
relays
•
Check CU input 20
•
Cable between the central unit
and the force transducer defec-
tive or loose. Water inside the
plug of the transducer
•
Force transducer defective
•
Check cable as well as
plugs, replace, if need be
•
Replace force transducer
E14
Below lower limit value
in measuring channel
"force main boom right"
•
Electronic component in the
measuring channel is defective.
•
Replace sensor unit
•
Cable between the central unit
and the angle sensor defective
or loose. Water inside the plug
of the angle sensor
•
Angle potentiometer defective
•
Check cable as well as
plugs, replace, if need be.
•
Replace angle sensor
E15
Below lower limit value
in measuring channel
"angle main boom"
•
Electronic component in the
measuring channel defective.
•
Replace sensor unit
E16
Below lower limit value
in measuring channel
"angle luffing jib"
•
Refer to E15
•
Refer to E15
E17
Below lower limit value
in measuring channel
"force luffing jib left"
•
Refer to E14
•
Refer to E14