Configuration
5.5 Adjusting the zero point (load/angle sensor only)
If load and angle sensors are connected, this function can be used to make subsequent small cor-
rections to the zero point.
Follow the procedure described below in order to adjust the zero point.
1.
Open the housing of the iFLEX TRS 14 as described in chapter 4.3.
43s
46s
50s
53s
abgleichen Sensor an Kanal 1
abgleichen Sensor an Kanal 2
abgleichen Sensor an Kanal 3
abgleichen Sensor an Kanal 4
▲
2.
Press and hold the
programming button
of the iFLEX TRS14 until:
- green and yellow
LED1 flash
(for adjustment of a sensor on
channel 1
)
- green and yellow
LED2 flash
(for adjustment of a sensor on
channel 2
)
- green and yellow
LED3 flash
(for adjustment of a sensor on
channel 3
)
- green and yellow
LED4 flash
(for adjustment of a sensor on
channel
4)
and then release the button. The previously flashing LEDs are now lit steadily.
The device remains in the ‘zero point adjustment’ mode.
3.
Now press the
programming button
of the iFLEX TRS14 again, several times if necessary, until:
- the
INFO
LED
lights up
(for adjustment in the
positive
direction)
- the
INFO
LED
extinguishes
(for adjustment in the
negative
direction)
and keep the button depressed until the desired zero point is reached.
The ‘zero point adjustment’ mode can only be terminated by disconnecting the central plug.
The previously set values thereby remain stored.
© 2010 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · E-mail: [email protected]
30
/37
21-810-19-0003_421830_en (Rev A).doc / 2010-08-31 / Issue A / rk.