![Hirschmann Dragon PTN User Manual Download Page 12](http://html1.mh-extra.com/html/hirschmann/dragon-ptn/dragon-ptn_user-manual_2137988012.webp)
12
Installation Dragon PTN Nodes
Release 01 02/2018
The meaning of the LEDs depends on the mode of operation (= boot or normal) in which the
NSM currently is running. After plugging in the module or rebooting it, the module turns into
the boot operation, see Table 3. After the module has rebooted successfully, after a few
seconds), the module turns into the normal operation, see LEDs in Table 4.
Table 3
LED Indications in Boot Operation
Cycle PSI1/2 PSO1/2
POE1/2
(only on NSM-A)
DI1/2
DO1/2
CSM1/2
1
x
x
---
---
---
---
2
x
x
---
---
x
---
3
x
x
---
---
---
---
x : LED is lit
--- : LED is not lit
The sub cycle times may vary.
The entire boot cycle time [1
à
3] takes only a few seconds.
Table 4
LED Indications in Normal Operation
LED
Color
Status
PSI1/2
Not lit, dark
The corresponding PSU does not receive input voltage from a power source.
Green
The corresponding PSU receives input voltage from a power source.
PSO1/2
Not lit, dark
The corresponding PSU does not d12V output voltage to the node.
Green
The corresponding PSU de12V output voltage to the node.
POE1/2
(only on
NSM-A)
Not lit, dark
The corresponding POE connector does not receive external power.
Green
The corresponding POE connector receives external power. This power can be used by the PoE
ports on the interface modules which are plugged into the node.
DI1/2
Not lit, dark
No activity or current has been detected on the corresponding input.
Green
Current has been detected on the corresponding input of the digital input connector (DI).
DO1
Not lit, dark
Minor
alarm is active on DO1 contact, DO1 contact is deactivated or idle, see §2.2.2g.
Green
No alarm is active on DO1 contact, DO1 contact is activated, see §2.2.2g.
DO2
Not lit, dark
Major
alarm is active on DO2 contact, DO2 contact is deactivated or idle, see §2.2.2g.
Green
No alarm is active on DO2 contact, DO2 contact is activated, see §2.2.2g.
CSM1/2
Not lit, dark
The corresponding CSM is not plugged in or, it is plugged in and in standby/passive mode in
case of redundant CSMs.
Green
The corresponding CSM is active.