28
Installation Dragon PTN Nodes
Release 01 02/2018
width:
482 mm / 18.98 inches;
height:
132.5 mm / 5.22 inches (3 U);
depth:
220 mm / 8.66 inches (including DIN Rail system).
Node XT-2206-A
width:
353.5 mm;
height:
132.5 mm / 5.22 inches (3 U);
depth:
220 mm / 8.66 inches (including DIN Rail system).
Node XT-1104-A
width:
211 mm / 8.31 inches;
height:
132.5 mm / 5.22 inches (3 U);
depth:
220 mm / 8.66 inches (including DIN Rail system).
3.6
Cooling
See §2.8.
3.7
Input Voltage Range
942 234-001: High voltage PSU 100 to 240 VAC ± 10 %;
942 234-002: Low voltage PSU 18 to 60 VDC;
942 234-003: High voltage PSU 88 to 300 VDC.
3.8
Digital Output Contacts
Maximum current: 1A DC;
Maximum voltage: 60V DC;
See also §2.2.2g;
3.9
Ordering Information
See Table 2.
4.
INSTALLATION INSTRUCTIONS
Instructions for node installation can be found in document Ref. [2] in Table 1.
CAUTION:
Double pole/neutral fusing.
CAUTION:
First connect the GND (Ground) to the housing of the node before connecting the mains
voltage. Only the mains voltage plug can disconnect the node’s mains voltage. For DC in-
put PSUs: never apply an excess input voltage and respect the correct polarity. The PSU
might get damaged when an incorrect voltage source has been connected!