background image

 

Installation Dragon PTN Nodes 

Release 01 02/2018

 

Table 15 Power Consumption ..................................................................................................... 27 

Summary of Contents for Dragon PTN

Page 1: ...elease 01 02 2018 https hirschmann support belden com User Manual Installation Dragon PTN Node PTN2210 1 NSM 2 PSUs 2 CSMs 10 IFMs Node PTN2209 1 NSM 2 PSUs 2 CSMs 9 IFMs Node PTN2206 1 NSM 2 PSUs 2 C...

Page 2: ...performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to th...

Page 3: ...17 2 3 1 Node PSUs 17 2 3 2 PoE PSUs only on NSM A 20 2 4 CSM Central Switching Module 24 2 4 1 General 24 2 4 2 CSM Redundancy 24 2 5 IFM Interface Module 24 2 6 Backplane 25 2 7 PE Protective Earth...

Page 4: ...Connection 21 Figure 18 Output Current Power Derating 22 Figure 19 DCPoE A PSU to NSM Connection 23 Figure 20 XT 2210 A Node Slot Speeds 24 Figure 21 XT 2209 A Node Slot Speeds 25 Figure 22 XT 2206 A...

Page 5: ...Installation Dragon PTN Nodes 5 Release 01 02 2018 Table 15 Power Consumption 27...

Page 6: ...and one central switching module CSM Each node provides a number of slots for interface modules to communi cate with applications like Ethernet SHDSL E1 T1 C37 94 Node XT 1104 A is ultra compact and...

Page 7: ...it for PTN2206 942 256 005 Heavy duty DIN Rail kit for PTN1104 942 229 001 Node Support Module PTN NSM A 942 229 002 Node Support Module PTN NSM B 942 234 001 PTN ACP A AC PSU 100 to 240 VAC 10 942 23...

Page 8: ...d from left to right see Figure 2 Node Support Module NSM 2 Power Supply Units PSU 1 PSU 2 10 Interface Modules IFM 1 IFM 10 2 Central Switching Modules CSM 1 CSM 2 Figure 2 XT 2210 A Node 2 1 2 Node...

Page 9: ...er Supply Unit PSU 4 Interface Modules IFM 1 IFM 4 1 Central Switching Module CSM Figure 5 XT 1104 A Node 2 2 NSM Node Support Module 2 2 1 General The NSM is required in each Dragon PTN node and perf...

Page 10: ...h The NSM can be replaced and is hot swappable Figure 6 NSM A NSM B Front Panel 2 2 2 Functions a Rotary DIP Switch Settings The Hardware Edition labeled as CARD_ID and Node Number on the NSM are set...

Page 11: ...ardware edition labeled as CARD_ID of the NSM has been factory set with rotary DIP switch S1 and S2 most significant and MUST NOT BE CHANGED d LED Indications PSI1 2 refers to the PSU input of the PSU...

Page 12: ...g PSU does not deliver 12V output voltage to the node Green The corresponding PSU delivers 12V output voltage to the node POE1 2 only on NSM A Not lit dark The corresponding POE connector does not rec...

Page 13: ...the NSM can pick up external events e g opening door and raise an appropriate alarm e g door opened with help text e g close the door and severity e g major These alarm properties can be assigned to...

Page 14: ...DC maximum voltage 60 VDC The DO connector in Figure 9 has following pin allocation Table 6 DO Pin Allocation Pin Contact Pin Name DO Output Description Alarm 1 DO1 C1 Out Common 1 Minor Alarms 2 DO1...

Page 15: ...o receive power from Power Sourcing Equipment PSE e g the Dragon PTN node Dragon PTN nodes are able to deliver PoE when one or two external PoE PSU s is are connected to the NSM via the PoE connectors...

Page 16: ...802 3af PoE and 802 3at PoE standard Via HiProvision it is possible to enable disable PoE per port and to verify which ports in each node are PoE enabled Future Power management is supported i e the...

Page 17: ...ng screws after plugging in the PSUs The AC power cable has a locking mechanism Both the DC PSUs and its power cable plug have unique coding keys see figures below A coding key is a physical obstructi...

Page 18: ...U 18 60VDC Power Cable Code Keys Table 7 DCP A PSU 18 60VDC Power Cable Code Keys Pin PSU Side Cable Side Code Key Code Key PE Code Key c DC PSU High Voltage PSU DCP B 942 234 003 input voltage 88 to...

Page 19: ...A node has one PSU slot available in which any of the PSUs can be used An empty PSU slot in the XT 2210 A XT 2209 A XT 2206 A node must be covered with a cover plate see Table 2 The total output of t...

Page 20: ...r temperature Overcurrent Input connector PCB side PC 4 3 G 7 62 and BF PC 4 Cable side PC 4 HV 3 STF 7 62 Table 11 Specifications DCP B PSU 88 300VDC Parameter Condition Remark Value Input Input volt...

Page 21: ...o 56V In normal conditions the continuously available power is 480W As of higher ambient tem peratures and as of an altitude of 2km derating occurs resulting in less available output cur rent and powe...

Page 22: ...1 years AC230V 45 years Weight 1 0 kg 2 2 lb Derating 12W C at 60 to 70 C see also figures below Dimensions WxHxD 65 x 124 x 127 mm 2 56 x 4 88 x 5 inches Protections Auto restart overload no load and...

Page 23: ...56VDC Output rated current 6 3A Output rated power 302 W General MTBF MIL HDBK 217F At 25 C GB 14 8 years Weight 1 2 kg 2 6 lb Derating 40 55 no derating 70 60 load by free air convection 70 no derat...

Page 24: ...ability of the services through a node if a CSM should fail If one fails the redundant hot standby CSM will take over automatically to the keep the node and all its services alive with a minimal servi...

Page 25: ...ditions can be read out via HiProvision 2 7 PE Protective Earth A PE Protective Earth point is provided on the left hand side panel of the node The PE connection ensures that all exposed conductive su...

Page 26: ...9 L3A L IFM see Ref 6 in Table 1 entirely fanless no moving parts The cooling in the Dragon PTN nodes occurs via natural convection For this reason no other equipment can be in stalled directly above...

Page 27: ...le NSM B 0 18 kg 0 4 lb AC PSU 100 to 240 VAC 10 0 91 kg 2 0 lb DC PSU 18 to 60 VDC 0 9 kg 2 0 lb DC PSU 88 to 300 VDC 0 9 kg 2 0 lb ACPoE A External DIN rail PSU AC 100 240 VAC Wide range Input 1 0 k...

Page 28: ...0 942 234 002 Low voltage PSU 18 to 60 VDC 942 234 003 High voltage PSU 88 to 300 VDC 3 8 Digital Output Contacts Maximum current 1A DC Maximum voltage 60V DC See also 2 2 2g 3 9 Ordering Information...

Page 29: ...u to use the appropriate take back systems These systems will reuse or recycle most of the materials of your end of life equipment in a sound way The crossed bin symbol invites you to use those system...

Page 30: ...owered Device PE Protective Earth PI Power Input PoE Power Over Ethernet PSE Power Source Equipment PSI Power Supply Input PSO Power Supply Output PSU Power Supply Unit PTN Packet Transport Network SH...

Reviews: