BAT-F, BAT-Rail, BAT54, BAT300
Release 02 07/10
35
2.7.2
BAT-Rail
Figure 7: BAT-Rail, wall mounting
Fasten on the wall mounting plate (width 120 mm / 4.73 in)
(see on
page 62 „Accessories“)
on a level wall surface using four screws.
Mount the device on the wall plate as shown in the illustration. Attach the
upper snap-in guide of the device into the rail and press it down against
the rail until it snaps into place.
2.8
Mounting/connecting external antennas
2.8.1
Connections for external antennas on BAT-F
The BAT-F devices have two to four connections for connecting external
antennas. These connections are N sockets.
The housing of the N socket and the signal connection are electrically
connected to the switching ground, the functional ground (FE) and the metal
housing of the device.
On delivery, the connectors are sealed with cover caps.
Unscrew the cover caps from the connectors to which you want to
connect external antennas.
BA
T300-Rail