background image

4

Use of tool for intended purpose

Main application

Type of screw

Drywall panels on metal framing

20 ga. (

0.88 mm)

Drywall screw with needle point, type S-DS01

Drywall panels on metal framing

20–14 ga. (

2.25 mm) Drywall screw with drill point, type S-DD01

Fastening metal framing parts to each other

Drywall screw with drill point, types S-DD02 and

(max. fastened thickness 12–13 ga. 2.50 mm)

S-DD03

Drywall panels on timber framing

Drywall screw with needle point, type S-DS03

Drywall panels on metal framing

20 ga. (

0.88 mm)

Drywall screw with needle point, type S-DS14

and timber framing
Particle board on timber framing

Drywall screw with needle point, type S-DS03

The tool can also be used with the SMI 55 magazine and corresponding magazined screws for the intended
applications. Please refer to the operating instructions for the SMI 55 drywall screw magazine.

4. Functional description

The SF 4000-A is a battery-powered drywall screwdriver
with automatic (jet) coupling designed for use by pro-
fessional drywall installers. For optimum efficiency and
comfort in use, we recommend that the tool is held in
line with the forearm (in-line grip)



. The motor cooling

air is drawn in through the slots

and is expelled from

the tool through the air exit

. The tool is suitable for

use by both right- and left-handed users. The ergonomic,
rubber-padded grip reduces fatigue and ensures that
the tool can be held securely.

The following items are supplied: electric screwdriver
with Phillips no. 2 bit and magnetic bit holder, 2 SFB 180
or SFB 185 batteries, C7/24 charger, 2 operating instruc-
tions, packed in a plastic toolbox. Alternatively, the elec-
tric screwdriver may be supplied with a Phillips no. 2 bit
and magnetic bit holder, operating instructions, packed
in a cardboard box.

See figure

and the explanations of operating controls

and components on page 1.

Main features of the tool

– Vibration-absorbing grip (synthetic rubber)
– Smooth speed control
– Gearing and clutch with permanent lubrication
– Automatic cut-out carbon brushes
– Coupling with jet function
– Scaffolding hook and belt hook (pivoting and

removable)

– Lockbutton for sustained operation
– Forward / reverse rotation
– Adjustable depth gauge
– Cooling air guidance (air exit)

Printed: 07.07.2013 | Doc-Nr: PUB / 5070681 / 000 / 00

Summary of Contents for SF4000-A

Page 1: ...SF4000 A 340751 340751 Operating instructions 1 8 Mode d emploi 9 16 Instrucciones de uso 17 24 Manual de instru es 25 32 USA CDN P E Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 2: ...1 This Product is Certified Ce produit est certifi Este producto esta certificado Este produto est certificado C US Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 3: ...2 Click 3 5 4 Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 4: ...6 Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 5: ...7 8 9 Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 6: ...R L STOP 15 16 10 11 12 13 14 Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 7: ...depth gauge with bit change function Screwdriver accessory interface click connection 1 4 chuck for bit holder magazine bit Cooling air exit Rating plate Clutch system gearing Scaffolding hook Belt ho...

Page 8: ...ger on the switch or insert ing the battery pack into a tool with the switch on invites accidents Remove adjusting keys or wrenches before turning the tool on A wrench or a key that is left attached t...

Page 9: ...ed and designed to filter out microscopic particles and direct dust away from the face and body Avoid prolonged contact with dust Wear protective clothing and wash exposed areas with soap and water Al...

Page 10: ...timum efficiency and comfort in use we recommend that the tool is held in line with the forearm in line grip The motor cooling air is drawn in through the slots and is expelled from the tool through t...

Page 11: ...s should be stored at room temperature Never store batteries where they are exposed to the heat of the sun on a radiator behind a motor vehicle windscreen or at a window Never use the battery until th...

Page 12: ...ting sustained operation The lockbutton for sustained operation can be used to keep the motor running constantly at the optimal speed with optimal motor cooling 1 Press the on off switch and hold it i...

Page 13: ...me 8 2 Care of the tool Before cleaning remove the battery from the tool in order to prevent inadvertent starting CAUTION Keep the power tool especially its grip surfaces clean and free from oil and g...

Page 14: ...ng direction of rotation to the left Speed suddenly drops Battery is almost exhausted Replace and charge the exhausted battery Battery becomes discharged more Battery condition is not optimal Charge t...

Page 15: ...and serviced properly and in accordance with the Hilti Operating Instructions and the technical sys tem is maintained This means that only original Hilti consumables components and spare parts may be...

Page 16: ...10 Printed 07 07 2013 Doc Nr PUB 5070681 000 00...

Page 17: ...111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2613 1109 10 Pos 3 1 Printed in Liechtenstein 2009 Right of technical and programme changes reserved S E O 340751 I...

Reviews: