7.10 Automatic alignment with the target plate
9
1. Set up the target plate with the reflective strips
facing the laser tool.
2. Press the target plate auto-centering button.
NOTE
This function may take up to 2 minutes before
starting.
The tool then searches for the target plate within its
alignment range (left/right).
7.11 Display while searching
9
@
The laser tool is not yet ready
for automatic alignment.
The tool has not yet completed the self-leveling procedure.
NOTE
This procedure will first be completed.
;
The display indicates stabiliz-
ation of the laser beam after
self-leveling.
Please wait until this operation has been completed.
=
The display indicates that
searching (auto centering)
is in progress.
Searching (auto centering) then begins.
%
Automatic alignment has
been completed.
Check the position of the laser spot on the target plate.
NOTE
If necessary, the remote control or the direction control buttons on
the tool (left / right) can be used to readjust the position of the beam.
&
Error during automatic align-
ment.
If the beam loses contact with the target plate while searching, the pro-
cedure must be restarted.
7.12 Selecting the laser beam mode
Press the laser beam mode button as often as necessary
until the desired display mode is shown in the display.
Constant beam
Blinking beam
High-power mode (only with the PP 25)
7.13 Adjusting the electronic bubble level
10
When the tool is pivoted, the bubble level appears clearly
in the display.
Adjust the tool until the “bubble” is in the center of the
display.
The LED begins to blink as soon as the tool’s compens-
ation range is exceeded.
7.14 Fitting the screw feet and centering screw
11
Fit the appropriate feet for the pipe diameter before
setting up the laser in the pipe.
NOTE
Feet are available in the sizes 150 mm, 200 mm, 250 mm
and 300 mm (6", 8", 10", 12").
7.15 Setting the target plate size
12
Set the target plate size to a value suitable for the pipe
diameter you are working with.
7.16 Target plate, front
12
@
Locking screw
Secures the target plate at the desired height.
;
Target plate, small
Target plate for 150 mm to 250 mm.
=
Bubble level
For setting up the target plate horizontally.
%
Target plate holder
For automatic alignment.
7.17 Target plate, rear (2)
12
&
Reflective strip
7.18 Setting parameters
7.18.1 Setting units of measurement to % or ‰
1. Press the ON / OFF button and the LOCK button at
the same time.
The set values are shown in the display.
2. Use the laser beam UP / DOWN button to move to
the “unit” line.
3. Select the value you wish to change by pressing the
direction control button.
4. Press the SET button to confirm the entry.
The tool then returns to the normal operating mode.
7.18.2 Setting and activating the security code
Unauthorized persons can be prevented from using the
laser tool by entering a 4-digit security code. Please note
that once the security code has been activated, the laser
tool can no longer be operated without entering this code.
The code will be requested automatically after the tool is
switched on.
1. Press the ON / OFF button and the LOCK button at
the same time.
The set values are shown in the display.
en
22