background image

Adhesive Anchoring Systems

HIT-HY 70 Hybrid for Masonry Construction 3.2.6

3.2.6

Hilti, Inc. (US) 1-800-879-8000  |  www.us.hilti.com  I  en español 1-800-879-5000  I  Hilti (Canada) Corp. 1-800-363-4458  I  www.hilti.ca  I  Anchor Fastening Technical Guide 2016   215   

3.2.6.1  Product description
3.2.6.2  Material specifications
3.2.6.3  Technical data
3.2.6.4  Installation instructions
3.2.6.5  Ordering information

Listings

/

Approvals

ICC-ES (International Code Council) 

ESR-2682

ICC-ES (International Code Council)

ESR-3342 URM

City of Los Angeles

Research Report No. 25947 URM only

LEED

®

 Credit 4.1-Low Emitting 

Materials

The Leadership in Energy and 

Environmental Design (LEED

®

) Green 

Building Rating system

TM

 is the nationally 

accepted benchmark for the design,  

construction and operation of high  

performance green buildings.

3.2.6.1 Product description

The Hilti HIT-HY 70 Adhesive Anchor 
System is used to anchor building 
components to grouted and ungrouted 
concrete block walls, solid and hollow 
brick walls and unreinforced multiple 
wythe brick walls referred to as 
unreinforced masonry or URM.

HIT-HY 70 is an injectable two-
component hybrid adhesive mortar. 
The two components are separated 
by means of a dual-cylinder foil pack 
attached to a manifold. An injection 
nozzle with an internal mixing element 
is attached to the manifold, and the 
adhesive components are dispensed 
through the injection nozzle to ensure 
their proper mixing. The injection nozzle 
may be replaced to permit interruptions 
in the use of the cartridges. Only 
injection tools and static mixing nozzles 
as recommended by the manufacturer’s 
printed installation instructions may  
be used.

The Hilti HIT-HY 70 Adhesive Anchor 
Systems consists of steel all thread 
rods, steel internally threaded inserts, 
combi inserts, reinforcing bars, plastic-
mesh screen tubes for installation only 
in unreinforced masonry (URM), hollow 
concrete block, and hollow brick walls, 
and the HIT-HY 70 Adhesive.

  

For clay tile, terracotta, and masonry 

applications that are not specifically 

addressed in this Technical Guide, 
please contact Hilti Technical Services.

Guide Specifications
Master Format Section:
Previous  2004 Format
03250 

03 16 00  Concrete   

   anchors
Related Sections: 
03200 

03 20 00  Concrete   

   reinforcing 
05050 

05 50 00  Metal   

   fabrications 
05120 

05 10 00  Structural metal  

   framing

Urethane Methacrylate injectable 
adhesive is used for installation  
of post-installed reinforcing steel, 
anchor rods and inserts into existing 
masonry and brick construction.  Hilti 
HIT-HY 70 is dispensed through 
side-by-side packs and mixed as the 
adhesive is dispensed through a static 
mixing nozzle

Plastic mesh screen tubes shall 
be used in conjunction with the 
injectable adhesive when reinforcing 
steel or  anchors are post-installed in 
unreinforced masonry (URM), ungrouted 
concrete block, brick with holes or 
other masonry construction with voids. 
The screen tubes are manufactured 
with a mesh size, length and diameter 
matched the anchor or reinforcing steel.

HIT-HY 70 adhesive,  HIT-SC screen 
tubes, HAS threaded rods, HIT-IC 
inserts and HIS-N insert shall be 
furnished by Hilti.

Installation shall be performed in 
accordance with the manufacturer's 
published installation instructions.

Table 1 - Properties of fully-cured HIT-HY 70 adhesive

Compressive strength

ASTM D695/DIN 53454

7,252-10,153 psi

50-70 MPa

Modulus of elasticity (Compression test)

ASTM D790/DIN 53452

246,568 psi

1,700 MPa

Water absorption

ASTM D570/DIN 53495

3-8 %

Electrical resistance

VDE/DIN 0303T3

4.2 x 10

11

  ohm/in.

1.065 x 10

12

 ohm/cm 

3.2.6.2 Material Specifications

For material specifications for anchor rods and inserts, please refer to section 3.2.9. 

Summary of Contents for Hit-hY 70

Page 1: ...luding data development product specifications general suitability installation corrosion and spacing and edge distance guidelines US http submittals us hilti com PTGVol2 CA http submittals us hilti com PTGVol2CA To consult directly with a team member regarding our anchor fastening products contact Hilti s team of technical support specialists between the hours of 7 00am 6 00pm CST US 877 749 6337...

Page 2: ...ds steel internally threaded inserts combi inserts reinforcing bars plastic mesh screen tubes for installation only in unreinforced masonry URM hollow concrete block and hollow brick walls and the HIT HY 70 Adhesive For clay tile terracotta and masonry applications that are not specifically addressed in this Technical Guide please contact Hilti Technical Services Guide Specifications Master Format...

Page 3: ...sonry cell 3 Linear interpolation of load values between minimum spacing smin and critical spacing scr and between minimum edge distance cmin and critical edge distance ccr is permitted 4 Concrete masonry thickness must be equal to or greater than 1 5 times the anchor embedment depth EXCEPTION the 5 8 inch and the 3 4 inch diameter anchors No 5 and No 6 bars may be installed in minimum nominally 8...

Page 4: ...nforcing bars in the top of grout filled concrete masonry walls1 2 3 4 5 6 Nominal anchor diameter or rebar size Effective embedment in mm Edge distance in mm 7 8 Minimum end distance in mm Tension lb kN Shear load lb kN 9 Load parallel to edge of masonry wall Load perpendicular to edge of masonry wall 1 2 4 1 2 114 1 3 4 44 5 8 203 1 165 5 2 815 3 6 345 1 5 4 101 6 1 625 7 2 1 445 6 4 505 2 3 5 8...

Page 5: ...onry 5 When using the basic load combinations in accordance with IBC Section 1605 3 1 tabulated allowable loads must not be increased for seismic or wind loading When using the alternative basic load combinations in IBC Section 1605 3 2 that include seismic or wind loads tabulated allowable loads may be increased by 33 1 3 percent or the alternative basic load combinations may be reduced by a fact...

Page 6: ...concrete block wall A maximum of two anchors for each cell of the hollow ungrouted concrete block is allowed 3 Anchors are not recognized for resisting earthquake forces For short term loading due to wind forces the allowable loads shall not be increased 4 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12 5 Tabulated embedment depth i...

Page 7: ...combined loading Tapplied Tallowable Vapplied Vallowable 1 Table 10 HIT HY 70 allowable adhesive bond loads for threaded rods in the face of hollow brick1 2 3 4 5 10 Nominal anchor diameter Effective embedment Tension Minimum edge distance cmin Load reduction factor cmin Shear Edge distance6 Critical ccr Minimum cmin Load reduction factor cmin in mm 6 lb kN 7 8 in mm 9 lb kN 7 8 in mm in mm 1 4 3 ...

Page 8: ...onfigurations on site testing is required to determine the actual performance of the anchor Allowable loads are calculated using a safety factor of 5 2 Tabulated embedment depth is limited by the length of the plastic HIT SC 16x50 mm screens See figure 11 3 The required concrete thickness is the thickness for which values are available and installation is recommended Anchors shall be installed alo...

Page 9: ... 30 min 20 min 10 min 7 min 4 min 2 min 1 min 5 6 10 11 20 21 30 31 40 41 42 50 51 68 69 86 87 104 10 min 10 min 7 min 4 min 2 min 1 min 23 32 33 41 42 50 51 68 69 86 87 104 5 0 1 5 6 10 11 20 21 30 31 40 3 2 6 4 Installation instructions Installation Instructions For Use IFU are included with each product package They can also be viewed or downloaded online at www us hilti com US and www hilti ca...

Page 10: ...hollow concrete block Threaded Rod Mesh Sleeve Approximate fastenings per foil pack1 Rod Size 5 8 Grade Embedment in Qty Nominal Bit Dia in Mesh Sleeve per Fastening 11 1 fl oz 330 ml 16 9 fl oz 500 ml Plastic Sleeve for 14 screw 2 20 1 2 1 HIT S 12 I 25 40 HAS B 1 4 x 3 2 20 1 2 1 SC 12x50 25 40 HAS B 1 4 x 4 1 2 3 1 8 20 1 2 1 SC 12x85 16 26 HAS B 5 16 x 3 2 20 5 8 1 SC 16x50 16 26 HAS B 5 16 x ...

Page 11: ... 2 In hollow material use with HIT SC 22 x 50 10 7 8 13 Internally Threaded HIT IC 1 2 3 x 3 16 In hollow material use with HIT SC 22 x 85 10 7 8 13 HIT Combi Insert HIT S 12 I Plastic sleeve for 14 screw 20 1 2 Multi wythe brick walls Threaded Rod Mesh Sleeve Approximate fastenings per foil pack1 Rod Size 5 8 Grade Embedment in Qty Bit Diameter in Mesh Sleeve per Fastening 11 1 fl oz 330 ml 16 9 ...

Reviews: