Description

Package Contents

Qty of Foil 

Packs

HIT-HY 70 (11.1 fl oz/330 ml)

Includes (1) foil pack with (1) mixer and 3/8-in. filler tube per pack

1

HIT-HY 70  Master Carton  

(11.1 fl oz/330 ml)

Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8-in. filler tube per pack

25

HIT-HY 70 Combo (11.1 oz/330ml)

Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8-in. filler tube per pack and (1) 

HDM 500 manual dispenser

25

HIT-HY 70 Master Carton  

(16.9 fl oz/500 ml)

Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8-in. filler tube per pack

20

HIT-HY 70 Combo (16.9 fl oz/500 ml)

Includes 2 master cartons containing (20) foil packs each with (1) mixer and 3/8-in. filler tube per pack 

and (1) HDM 500 manual dispenser

40

HIT-RE-M Static Mixer

For use with HIT-HY 70 cartridges

1

Brick with holes and hollow concrete block

Threaded Rod 

Mesh Sleeve

Approximate fastenings per foil pack

1

Rod Size 5.8 Grade

Embedment, in.

Qty

Nominal Bit Dia., in.

Mesh Sleeve per Fastening

11.1 fl oz (330 ml)

16.9 fl oz (500 ml)

Plastic Sleeve (for #14 screw)

2

20

1/2

(1) HIT S-12/I

25

40 

HAS B 1/4 x 3  

2

20

1/2

(1) SC 12x50

25

40

HAS B 1/4 x 4-1/2  

3-1/8

20

1/2

(1) SC 12x85

16

26

HAS B 5/16 x 3  

2

20

5/8

(1) SC 16x50

16

26

HAS B 5/16 x 4-1/2  

3-1/8

20

5/8

(1) SC 16x85

7

12

HAS-E 3/8 x 3

2

10

5/8

(1) SC 16x50

16

26 

HAS-E 3/8 x 4-3/8

3-1/8

10

5/8

(1) SC 16x85

7

12 

HAS-E 1/2 x 3-1/8

2

10

11/16

(1) SC 18x50

9

15 

HAS-E 1/2 x 4-1/2

3-1/8

10

11/16

(1) SC 18x85

4

7

Customize the sleeve to the 
length of your application.  

Different embedment depths 

are created with minimal effort.

Step 1: Remove the centering ring of 

any screen tube within the cell. 

Step 2: Pierce the tip of the screen tube 

with the rod intended to be use to check 

embedment depth. 

Step 3: Combine screen tubes to 

desired length.

3.2.6.5 Ordering information

HIT-IC Internally Threaded Insert

Bent Threaded Rod 22.5 degrees

 

with Nut and Washer

HAS-E Threaded Rod with 

 

Nut and Washer 

Reinforcing Bar/Rebar supplied by contractor

HIT-HY 70  

(16.9 fl oz/500 ml)

Mixing Nozzle

Adhesive Pack 

Holder

HIT-HY 70  

(11.1 fl oz/330 ml)

HDE 500 

 

Battery 

Dispenser

HDM 500

 

Manual

Dispenser

Summary of Contents for Hit-hY 70

Page 1: ...luding data development product specifications general suitability installation corrosion and spacing and edge distance guidelines US http submittals us hilti com PTGVol2 CA http submittals us hilti com PTGVol2CA To consult directly with a team member regarding our anchor fastening products contact Hilti s team of technical support specialists between the hours of 7 00am 6 00pm CST US 877 749 6337...

Page 2: ...ds steel internally threaded inserts combi inserts reinforcing bars plastic mesh screen tubes for installation only in unreinforced masonry URM hollow concrete block and hollow brick walls and the HIT HY 70 Adhesive For clay tile terracotta and masonry applications that are not specifically addressed in this Technical Guide please contact Hilti Technical Services Guide Specifications Master Format...

Page 3: ...sonry cell 3 Linear interpolation of load values between minimum spacing smin and critical spacing scr and between minimum edge distance cmin and critical edge distance ccr is permitted 4 Concrete masonry thickness must be equal to or greater than 1 5 times the anchor embedment depth EXCEPTION the 5 8 inch and the 3 4 inch diameter anchors No 5 and No 6 bars may be installed in minimum nominally 8...

Page 4: ...nforcing bars in the top of grout filled concrete masonry walls1 2 3 4 5 6 Nominal anchor diameter or rebar size Effective embedment in mm Edge distance in mm 7 8 Minimum end distance in mm Tension lb kN Shear load lb kN 9 Load parallel to edge of masonry wall Load perpendicular to edge of masonry wall 1 2 4 1 2 114 1 3 4 44 5 8 203 1 165 5 2 815 3 6 345 1 5 4 101 6 1 625 7 2 1 445 6 4 505 2 3 5 8...

Page 5: ...onry 5 When using the basic load combinations in accordance with IBC Section 1605 3 1 tabulated allowable loads must not be increased for seismic or wind loading When using the alternative basic load combinations in IBC Section 1605 3 2 that include seismic or wind loads tabulated allowable loads may be increased by 33 1 3 percent or the alternative basic load combinations may be reduced by a fact...

Page 6: ...concrete block wall A maximum of two anchors for each cell of the hollow ungrouted concrete block is allowed 3 Anchors are not recognized for resisting earthquake forces For short term loading due to wind forces the allowable loads shall not be increased 4 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12 5 Tabulated embedment depth i...

Page 7: ...combined loading Tapplied Tallowable Vapplied Vallowable 1 Table 10 HIT HY 70 allowable adhesive bond loads for threaded rods in the face of hollow brick1 2 3 4 5 10 Nominal anchor diameter Effective embedment Tension Minimum edge distance cmin Load reduction factor cmin Shear Edge distance6 Critical ccr Minimum cmin Load reduction factor cmin in mm 6 lb kN 7 8 in mm 9 lb kN 7 8 in mm in mm 1 4 3 ...

Page 8: ...onfigurations on site testing is required to determine the actual performance of the anchor Allowable loads are calculated using a safety factor of 5 2 Tabulated embedment depth is limited by the length of the plastic HIT SC 16x50 mm screens See figure 11 3 The required concrete thickness is the thickness for which values are available and installation is recommended Anchors shall be installed alo...

Page 9: ... 30 min 20 min 10 min 7 min 4 min 2 min 1 min 5 6 10 11 20 21 30 31 40 41 42 50 51 68 69 86 87 104 10 min 10 min 7 min 4 min 2 min 1 min 23 32 33 41 42 50 51 68 69 86 87 104 5 0 1 5 6 10 11 20 21 30 31 40 3 2 6 4 Installation instructions Installation Instructions For Use IFU are included with each product package They can also be viewed or downloaded online at www us hilti com US and www hilti ca...

Page 10: ...hollow concrete block Threaded Rod Mesh Sleeve Approximate fastenings per foil pack1 Rod Size 5 8 Grade Embedment in Qty Nominal Bit Dia in Mesh Sleeve per Fastening 11 1 fl oz 330 ml 16 9 fl oz 500 ml Plastic Sleeve for 14 screw 2 20 1 2 1 HIT S 12 I 25 40 HAS B 1 4 x 3 2 20 1 2 1 SC 12x50 25 40 HAS B 1 4 x 4 1 2 3 1 8 20 1 2 1 SC 12x85 16 26 HAS B 5 16 x 3 2 20 5 8 1 SC 16x50 16 26 HAS B 5 16 x ...

Page 11: ... 2 In hollow material use with HIT SC 22 x 50 10 7 8 13 Internally Threaded HIT IC 1 2 3 x 3 16 In hollow material use with HIT SC 22 x 85 10 7 8 13 HIT Combi Insert HIT S 12 I Plastic sleeve for 14 screw 20 1 2 Multi wythe brick walls Threaded Rod Mesh Sleeve Approximate fastenings per foil pack1 Rod Size 5 8 Grade Embedment in Qty Bit Diameter in Mesh Sleeve per Fastening 11 1 fl oz 330 ml 16 9 ...