18
4. Technical data
Power supply
Electric power supply
Mains voltage:
400 V, 3-phase, 50 Hz
Fuse rating:
At least 32 amps,
63 amps recommended
Generator:
60 kVA recommended
The generator must be earthed when in operation
Water supply for hydraulic unit, saw head and saw
blades
Cooling water:
7 l/min. at 4–6 bar; temp. 20°
Dimensions and weights
D-LP 32 hydraulic unit
L
×
B
×
H
790
×
540
×
1090 mm
Weight with oil
220 kg
remote control unit D-RC-LP 32
L
×
B
×
H
390
×
180
×
120 mm
Weight
2.2 kg
DS-TS 32 saw head
L
×
B
×
H
510
×
380
×
400 mm
Weight
36 kg
IP protection code
D-LP 32 hydraulic unit:
IP 44
D-RC-LP 32 remote control unit:
IP 65
4.1
4.2
4.3
Climatic conditions for operation
and storage
■
The nominal values given in the data for the
D-LP 32 /DS-TS 3 2 hydraulic saw system are applic-
able at ambient temperatures within the –15°C to
+45°C range (hydraulic unit warmed up in advance
at temperatures below zero).
■
When dry, the units can be stored at temperatures
between –15°C and +50°C.
4.4
Printed: 08.07.2013 | Doc-Nr: PUB / 5069667 / 000 / 01
Summary of Contents for D-LP 32
Page 1: ...Operating instructions en D LP 32 DS TS 32 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Page 20: ...20 4 Technical data Rating plates 4 7 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Page 42: ...42 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Page 53: ...53 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Page 54: ...54 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...
Page 55: ...55 Printed 08 07 2013 Doc Nr PUB 5069667 000 01 ...