8
English
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This may significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: Maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values in accordance with EN 60745
AG 230-24D
Sound (power) level (L
WA
)
105 dB(A)
Emission sound pressure level (L
pA
)
94 dB(A)
Uncertainty for the sound pressure level
(K
pA
)
3 dB(A)
Total vibration (vector sum of three directions), measured in accordance with EN 60745-2-3
Other applications, such as cutting, may produce vibration values that deviate from the given values.
AG 230-24D
Surface grinding with the
vibration-absorbing side handle (a
h,AG
)
5.8 m/s²
Uncertainty (K)
1.5 m/s²
6 Operation
6.1 Preparations at the workplace
CAUTION
Risk of injury!
Inadvertent starting of the product.
▶
Unplug the supply cord before making adjustments to the power tool or before changing
accessories.
Observe the safety instructions and warnings in this documentation and on the product.
6.2 Fitting the side handle
▶
Screw the side handle into one of the threaded bushings provided.
6.3 Guard or guard with cover plate
▶
Observe the instructions for fitting the applicable guard.
6.3.1 Fitting the guard or guard with cover plate
Note
The keying on the guard ensures that only a guard designed for use with the power tool can be fitted.
The keyed locating lug also prevents the guard from coming into contact with the disc.
1. Release the clamping lever.
2. Fit the guard onto the arbor collar so that the keyed locating lug engages in the recess provided.
3. Rotate the guard into the desired position.
4. Secure the guard by closing the clamping lever.
Note
The guard is already set to the correct tension by way of the adjusting screw. If the tension is too
low when the guard is fitted, the adjusting screw can be tightened slightly to increase the tension.
6.3.2 Adjusting the guard or guard with cover plate
1. Release the clamping lever.
2. Rotate the guard to the required position.
3. Secure the guard by closing the clamping lever.
Printed: 17.11.2016 | Doc-Nr: PUB / 5313035 / 000 / 01
Summary of Contents for AG 230-24D
Page 2: ...1 Printed 17 11 2016 Doc Nr PUB 5313035 000 01 ...
Page 3: ...2 3 4 5 Printed 17 11 2016 Doc Nr PUB 5313035 000 01 ...
Page 4: ...6 7 Printed 17 11 2016 Doc Nr PUB 5313035 000 01 ...
Page 5: ...8 9 Printed 17 11 2016 Doc Nr PUB 5313035 000 01 ...
Page 204: ...198 中文 Printed 17 11 2016 Doc Nr PUB 5313035 000 01 ...
Page 205: ...Printed 17 11 2016 Doc Nr PUB 5313035 000 01 ...