HIKVISION IR Smart Speed Dome User Manual Download Page 43

User Manual of IR Smart Speed Dome 

© Hikvision Digital Technology Co., Ltd. All Rights Reserved.

 

37 

 

Exposure 

compensation 

White balance 

Auto 

Auto-flip 

On 

Proportional pan 

On 

Park time 

5 seconds 

Park action 

None 

Scan speed 

Level 28 

Limit stops 

Off 

Time display 

Off 

Zoom,   

azimuth/elevation and 

preset label display 

Display for 2 seconds 

 

3.7.4

 

Restoring Default Camera Settings 

Enter 

MAIN MENUS > RESTORE CAMERA 

Click 

IRIS+ 

to restore the camera settings to the default value; or click

 IRIS- 

to exit.

 

Note:

 Camera settings include the image parameters, lens settings and display settings. 

3.7.5

 

Rebooting the Dome 

Enter 

MAIN MENUS > REBOOT DOME 

and click

 IRIS+

 to reboot the speed dome remotely.

Summary of Contents for IR Smart Speed Dome

Page 1: ...Hikvision Digital Technology Co Ltd All Rights Reserved IR Smart Speed Dome User Manual UD 6L0201D1135A01...

Page 2: ...ot hesitate to contact the dealer This manual is applicable to IR Smart Speed Dome This manual may contain several technically inaccurate points or printing errors and the content is subject to change...

Page 3: ...ce must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with C...

Page 4: ...over heat or fire hazard Please make sure that the power has been disconnected before you wire install or dismantle the speed dome When the product is installed on wall or ceiling the device shall be...

Page 5: ...e cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover Please use a soft and dry cloth when clean inside and outside s...

Page 6: ...3 3 2 Configuring Privacy Mask 17 3 3 3 Configuring OSD Settings 19 3 4 Configuring PTZ Control Parameters 21 3 4 1 Configuring PTZ Parameters 21 3 4 2 Configuring Presets 23 3 4 3 Configuring Patrols...

Page 7: ...an be controlled by the control keyboard DVR matrix etc Limit Stops The dome can be programmed to move within the limit stops left right up down which are configurable by the control keyboard DVR or c...

Page 8: ...a to focus automatically to maintain clear video images DAY NIGHT Auto switch The speed dome delivers color images during the day as light diminishes at night it switches to night mode and delivers bl...

Page 9: ...ormally closed And the alarm dwell time is configurable as well Manchester Code Self test The speed dome supports Manchester code self test for fault diagnostic You can enable the Manchester code diag...

Page 10: ...485 Failure Diagnostics In the presence of failure at the transmitting and receiving terminals of RS 485 communications the speed dome is capable of performing self test and detecting the fault result...

Page 11: ...ions of the System Information System Info Description TYPE The model of the speed dome SN The serial number of the speed dome ADDRESS The default communication address of the speed dome COM Format Th...

Page 12: ...can choose the preset number from the list in the PTZ control panel Please refer to table below for details For instance preset 99 is the Start auto scan If you call the preset 99 the speed dome star...

Page 13: ...0 Set Pattern 1 72 Call Pattern 3 71 Set Pattern 2 72 Set Pattern 3 2 4 On Screen Displays The speed dome supports following on screen displays Zoom Identifies the amount of magnification The format i...

Page 14: ...PRIVACYS ALARMS AUXS CLEAR SETTINGS FOCUS ZOOM LIMIT ZOOM SPEED SLOW SHUTTER AUTO FLIP PROPORTION AL PAN PARK ACT SCAN SPEED IMAGE FREEZE DOME SPEED PRESET PEED LIMIT STOP PARK TIME REBOOT DOME LANGU...

Page 15: ...the speed dome 4 Call preset 95 from the preset list in the PTZ control panel of the DVR MAIN MENUS SYS INFO DOME SETTINGS RSTORE DEFAULTS RSTORE CAMERA RSBOOT DOME LANGUAGE ENGLISH SET TITLE OFF EXIT...

Page 16: ...t system information of the speed dome as shown in Figure 3 2 including model address protocol etc The information shown on this submenu is similar to the system information shown after the power up a...

Page 17: ...255 If the SOFT ADDR ACTIVE is set as OFF the hard address set by the DIP switch is the valid address of the speed dome Task 2 Set the broadcast address of the speed dome When the BROADCAST ADDRESS i...

Page 18: ...left right up down direction buttons to adjust the view angle 3 Click IRIS button to confirm and exit IR LED Parameters IR PARAMETER IR SENSITIVITY LOW N M LED CURRNT 2 FAR LED CURRNT 2 REFERENCE HEI...

Page 19: ...menu Protocol settings You can set the PROTOCOL STATUS SET as ON or OFF and set the PROTOCOL SET as AUTO MATCH PELCP P PELCO D Private code etc RS 485 checksum setting You can set the 485CHECK SET as...

Page 20: ...ting and zooming 3 Click IRIS button to save the settings Setting the focus limit Purpose This function is used to limit the minimum focus distance You can configure the focus limit longer when the ta...

Page 21: ...he shutter speed Purpose The speed of the electronic shutter controls the amount of light entering the lens in a unit of time a second You can manually configure the shutter speed for the speed dome a...

Page 22: ...u can switch it to DAY mode in normal lighting conditions Note You can also call preset 39 to set the IR cut filter mode to DAY mode and call preset40 to set it as NIGHT mode 2 D N level The D N level...

Page 23: ...OMP value from 0 to 14 The default value is 7 White balance You can set WHITE BALANCE mode as AUTO INDOOR OUTDOOR SELFDEF self defined ATW auto tracking and HAUTO half auto AUTO In Auto mode the dome...

Page 24: ...wn direction buttons to select a mask number for configuration 3 Click IRIS again to confirm and exit the editing mode Note The configurable privacy mask numbers vary depending on the camera models 3...

Page 25: ...play of the dome name PTZ control information viewing direction etc Display the dome title Steps 1 Enter the dome title setting menu MAIN MENUS SET TITLE 2 Click IRIS to enter the editing mode 3 Click...

Page 26: ...e title in the lower right corner or call preset 13 twice within 5 seconds to exit the title setting menu and display the title in the lower left corner or call preset 14 twice within 5 seconds to exi...

Page 27: ...heast East Southeast South Southwest West Northwest Note The due north direction is 0 It is also the factory default initial position 3 4 Configuring PTZ Control Parameters Purpose You can configure p...

Page 28: ...in the process of performing external alarm linked actions Image freeze This feature enables the live view to switch directly from one scene defined by a preset to another without showing the middle a...

Page 29: ...ply click the calling button to view the desired image position TASK 1 Set a preset Steps 1 Move the cursor to enter preset configuration submenu MAIN MENUS DOME SETTINGS PRESETS PRESETS PRESET NUM 1...

Page 30: ...he letter number symbol list to the label 5 Click FOCUS to exit the character lists and click IRIS again to confirm and exit the submenu LABEL PRESET 1 INS LOWCASE a b c d e f g h I j ZOOM DELETE CONT...

Page 31: ...configuration submenu MAIN MENUS DOME SETTINGS PATROLS 2 Choose the patrol number Steps 1 Move the cursor to PATROLS NUM and click IRIS to enter edit mode 2 Click the up and down direction buttons to...

Page 32: ...sequence for a patrol Press IRIS to save the current settings or press IRIS to cancel and return to the previous menu Task 2 Preview the patrol Move the cursor to PREVIEW and click IRIS to preview th...

Page 33: ...NING 100 BACK EXIT Figure 3 19 Pattern Configuration Menu Task 1 Set a pattern Steps 1 Move the cursor to enter the PATTERNS submenu MAIN MENUS DOME SETTINGS PATTERNS 2 Choose the pattern number Steps...

Page 34: ...RIS to delete the pattern Note If you delete the current pattern the following pattern will also be deleted E g if pattern 2 is deleted pattern 3 and pattern 4 will be deleted as well Clear all the pa...

Page 35: ...he cursor to TASK ACTION and click the IRIS to enter edit mode 2 Click the up and down direction buttons to select the task action from preset 1 to 8 pattern 1 to 4 patrol 1 to 8 panning scan tilting...

Page 36: ...ve the cursor to CLEAN TASK and click IRIS to delete the time and action of the current task 3 4 6 Configuring Zones Purpose ZONE submenu is used to divide the scene into several parts with user defin...

Page 37: ...one it will switch to ON automatically if you delete the zone the ZONE STATUS will switch to OFF Task 2 Clear the zone settings Move the cursor to CLEAR ZONE and click IRIS to clear all the settings o...

Page 38: ...LT LOST 0 CAMERA LOST 0 BACK EXIT Figure 3 26 Self diagnostics 3 5 Configuring Smart Settings Purpose The speed dome tracks the moving objects automatically after you configure this function Steps 1 E...

Page 39: ...configured 3 Click IRIS again to confirm and exit edit mode of this column Note You can configure up to 7 alarms 3 Configure the alarm input Steps 1 Move the cursor to ALARM INPUT and click the IRIS...

Page 40: ...the next one after the user defined interval You can set the on ALARM SEQUENCE submenu from 1 to 200 seconds 3 Configure the alarm rest delay If there s a linkage action has already been triggered by...

Page 41: ...er that you want to link the auxiliary output to 2 Move the cursor to AUX and click IRIS to configure the auxiliary output to the alarm You can choose NONE to disable auxiliary alarm outputs choose 1...

Page 42: ...E OPEN QUIT CLOSE Figure 3 30 Set the Password 3 7 3 Restoring Default Dome Settings Purpose You can reset all dome settings to factory default parameters as shown in the table below Note Dome setting...

Page 43: ...s Off Time display Off Zoom azimuth elevation and preset label display Display for 2 seconds 3 7 4 Restoring Default Camera Settings Enter MAIN MENUS RESTORE CAMERA Click IRIS to restore the camera se...

Page 44: ...Hikvision Digital Technology Co Ltd All Rights Reserved...

Reviews: