background image

Non-Visible Panic Alarm Station Configuration Guide 

2) Change the device IP address to the same subnet with your computer and set port number as 

80. 

3) Enter the admin password of the device and click OK to complete modification. 

10. Optional: Check the device on the online device list and click Add to add the device to the 

device list. 

Summary of Contents for DS-PEA101 Series

Page 1: ...Non Visible Panic Alarm Station Configuration Guide...

Page 2: ...E PRODUCT BY YOU IS AT YOUR OWN RISK IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFIT...

Page 3: ...CTION OF CHEMICAL OR BIOLOGICAL WEAPONS ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE OR IN SUPPORT OF HUMAN RIGHTS ABUSES IN THE EVENT OF ANY CONFLICTS B...

Page 4: ...nger Indicates a hazardous situation which if not avoided will or could result in death or serious injury Caution Indicates a potentially hazardous situation which if not avoided could result in equip...

Page 5: ...ct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet...

Page 6: ...k Configuration 6 3 2 1 Basic Settings 6 3 2 2 Set DNS 8 3 2 3 Set NAT 8 3 2 4 Set Alarm Center 10 3 2 5 Set SIP 11 3 2 6 Set Hik Connect 13 3 2 7 Access the Platform 14 3 2 8 Set Intercom Parameters...

Page 7: ...rameters 31 3 6 4 Set Intercom Audio 31 3 7 System Settings 32 3 7 1 Set Time 32 3 7 2 Set System Parameters 33 3 7 3 Set Security 33 3 7 4 Set Password 34 3 7 5 Set User 35 3 7 6 Search for Log 35 3...

Page 8: ...1 channel alarm output It supports center call two way video intercom real time monitoring first time alarm help and audio anomaly detection It can provide faster and more effective services for the...

Page 9: ...s show how to activate a device and modify its IP address For batch activation and IP addresses modification refer to User Manual of SADP for details Steps 1 Run the SADP software and search the onlin...

Page 10: ...ect the Cloud P2P Region and login the Cloud P2P account Note For the first use you need to register a cloud P2P account After logging in you can store your device on the cloud 3 Enter Device Manageme...

Page 11: ...device IP address to the same subnet with your computer and set port number as 80 3 Enter the admin password of the device and click OK to complete modification 10 Optional Check the device on the onl...

Page 12: ...re configure it See Add Device to the Client Software Get the client software from the technical support and install the software according to the prompts 3 1 Device Management 3 1 1 Add Device to the...

Page 13: ...ough the SADP software the client software or the device The SADP software is taken as an example for explanation Steps 1 Run the SADP software check the activated device and edit the IP Address Subne...

Page 14: ...the NIC type 3 Set the network address Automatically obtain the network address Check Auto obtain the device automatically obtains the network address IPv4 Address Subnet Mask IPv4 Gateway Address IP...

Page 15: ...it can be changed to any port No ranges from 1024 to 65535 5 Click Save to save the settings 3 2 2 Set DNS When the device accesses the network through the domain name you need to configure the correc...

Page 16: ...e Remote Configuration page go to Network NAT Figure 3 4 NAT Setting Page 2 Check Enable UPnP and set Mapping Types as Manual or Auto Set Mapping Types as Auto The Ports are read only and the external...

Page 17: ...protocol port please make sure that the port you modified is available By default the value of the RTSP port No is 554 3 Click Save to save the settings 3 2 4 Set Alarm Center Configure the alarm cen...

Page 18: ...User Name Supports numbers and letters The HIK protocol can be set to a length ranging from 6 to 9 digits Note If you set the protocol type as HIK you do not need to edit the user name 4 Click Save 3...

Page 19: ...e between 1024 and 65535 Local Listening Port The local port of the device SIP function By default it is 5060 the available server port number should be between 1024 and 65535 5 Configure the SIP para...

Page 20: ...whether the wired network is normal when you select a wireless network only the wireless network is used Register User Name The user name which the device registers to the SIP server Registration Pas...

Page 21: ...e The default server address is litedev hik connect com 4 Select Network Mode 5 Enter a verification code and click Generate QR code There will be a QR code displaying on the page 6 Click Save 7 Scan...

Page 22: ...Port Enter the port number of the platform Panel ID Panel ID is the unique identification of the device The device ID length ranges from 6 to 9 Communication Network Select the network mode for commun...

Page 23: ...9 Set Integrate Protocol Parameters If you need to access to the device through ONVIF protocol you can configure the ONVIF user to enhance the network security Steps 1 Click to enter the Remote Config...

Page 24: ...The default zone has a default zone type default audio file and the default zone will automatically upload an alarm recovery report These three parameters Zone Type Audio File and Upload Alarm Recove...

Page 25: ...In the armed state as long as the detector connected to the zone is triggered an alarm is generated immediately without delay Fire Zone The fire zone must be set to a 24 hour alarm zone When the fire...

Page 26: ...The relay output can set the output delay time that is when the zone is triggered the trigger outputs a signal and the trigger will turn off the output after the output delay time ends Please refer to...

Page 27: ...e zone event is triggered the relay will turn off the relay output after the output delay time is ended 3 Click Save 4 Optional Click Copy to you can copy the relay settings to other relays 3 3 3 Set...

Page 28: ...alling tone when calling can be set from 40 s to 80 s Waiting Time The extended playback time of the prompt tone based on the maximum ring time when calling the master station and pressing the call wa...

Page 29: ...Edit the time period Modify the time period Click and select the added time period drag to modify the time period position click and select the added time period then moves the cursor to both ends of...

Page 30: ...nt Relay Figure 3 21 Relay Management Page Check the relays that need to be turned on off Click Enable Locked to change the relay switch status Click Refresh you can refresh the relay switch status 3...

Page 31: ...a 3 5mm hole interface which can connect to the external microphones and speakers The device defaults to micIn and spkOut In the audio output mode the volume of spkOut and lineOut1 can be set indepen...

Page 32: ...4 Manage Audio File Upload the custom audio files to SD card and delete the audio file in the SD card Before You Start Insert the SD card into the device Steps 1 Click to enter the Remote Configurati...

Page 33: ...the same name 3 Optional Delete the audio files in the SD card 1 In the File List click Refresh to display the audio files 2 Check the audio file needs to be deleted click Delete The function using t...

Page 34: ...e and set the arming schedule for audio exception detection Note There are three schedules The schedule template not editable that comes with the system such as all day template weekday template and e...

Page 35: ...and audio parameters Click Save to save the settings Note You can click Copy to to copy the parameters to other camera After editing the video and audio parameters the device won t reboot Please comb...

Page 36: ...e smaller the code stream fluctuation is but the image quality is relatively poor Otherwise the code stream fluctuation is larger and the image quality is higher It is recommended to use the default v...

Page 37: ...the drop down box to configure the display parameters of the camera including display position display format and optional display content you are able to add custom display information Editing the d...

Page 38: ...ra Name text box and click Save Adding custom display content Click the right area of the check box in the Text Overlay List and enter display content in the text box Check the text and click Save to...

Page 39: ...t the Audio Encoding Type as G711_U PCM ADPCM AAC or OPUS from the drop down box And click Save to save the settings Note EZVIZ intercom only supports G711_U and AAC 3 7 System Settings 3 7 1 Set Time...

Page 40: ...m General Parameters Figure 3 37 System Parameters Setting Page Set the device name and device No Click Save to save the settings 3 7 3 Set Security Enable disable SSH service which is used to provide...

Page 41: ...ked user logs Unlock The user s access lock status on the corresponding IP address 2 Enable the access lock function and set the lock parameters 1 Check Access Lock to enable the access lock function...

Page 42: ...to System User 2 Edit the admin user password 1 Select the admin user and click Edit 2 Enter the new password and confirm it 3 Click Save Figure 3 40 Edit Admin User 3 7 6 Search for Log Search and v...

Page 43: ...n Guide 36 Figure 3 41 Search and View the Log Note You can click Backup and download the search result 3 7 7 Maintain the System System management and remote upgrade Click to enter the Remote Configu...

Page 44: ...f the device will be restored to factory default settings Restore All Restore all the parameters to factory default settings and the device needs to be reactivated after restoring the parameters to de...

Page 45: ...efore the upgrade Caution Do not power off the device during the upgrade process 3 7 8 Check Video Audio Status Automatically or Manually check the video and audio status Click to enter the Remote Con...

Page 46: ...results are displayed in the list Table 3 1 Description of Check Results Check results Description Normal Video audio input audio output signal is normal Abnormal Video audio input audio output signal...

Page 47: ...Configuration page go to Status Zone you can view the status of zone alarm 3 8 2 Check Relay Status Click to enter the Remote Configuration page go to Status Relay you can view the relay status 3 8 3...

Page 48: ...Non Visible Panic Alarm Station Configuration Guide 41 Scan the QR code to get the device command...

Page 49: ...UD24610B...

Reviews: