UART1 Jumper Cap
Use the jumper cap to switch the serial port communication mode with the main lane
controller. You can switch between the RS-485 communication mode and the RS-232
communication mode. By default, it is in RS-485 communication mode.
Lane
Use the jumper cap to switch the serial port communication mode with the lane controller. By
default, the interface is wired and it is in RS-485 communication mode. If wiring other
controllers (compatible with Hikvision communication protocol), use the jumper cap to switch
between RS-485 and RS-232 communication mode.
UART4
The serial port is in the wiring interface according to the picture above, which has a fixed RS-232
communication mode to communicate with the main lane controller. It contains no jumper cap
and cannot change the communication mode.
UART7/UART8
Reserved serial port. The serial port has a fixed RS-232 communication mode. It contains no
jumper cap and cannot change the communication mode, which can connect with a QR code
scanner.
The reserved interface positions in the turnstile and their corresponded UART No. are as follows:
Note
The diagram is for reference only.
DS-K3B601SX Series Swing Barrier Quick Start Guide
21