background image

Face Recognition Swing Barrier Installation Guide_V1.1-20190215.docx 

Product  Support  Team 

14 

 

   

 

 

2)

 

Add user info and card number; 

   

 

 

3)

 

Add permission group and synchronize to device; 

 

 

Summary of Contents for DS-K3B601

Page 1: ...Installation Guide_V1 1 20190215 docx Product Support Team 1 Face Recognition Swing Barrier Installation Guide Date Content Person 20180320 Creat Ciel 20180409 Modify Nero 20180719 Translation and Modify Morgen 20190215 Modify Morgen ...

Page 2: ...f Structure 3 1 2 Device Model 4 1 3 Parameters 5 2 Installation Guide 6 2 1 Installation for swing barrier 6 2 2 Barrier Wiring 7 2 3 Face recognition terminal wiring 9 3 Configuration and Debug 11 3 1 Configure K3M200 barrier control board 11 3 2 Configure face recognition terminal 12 3 3 Permission configuration on iVMS 4200 client software 13 3 4 Testing 15 Appendix FAQ 15 ...

Page 3: ... 4200 through card issuer or fingerprint enrollment station Face will be registered from enrollment device or import from PC to iVMS 4200 then these cards and faces will be synchronized to terminals DS K5603 Z card number fingerprint and permission will be synchronized to barrier control board DS K3M200 in swing barrier The fingerprint data will be send to fingerprint reader optional from barrier ...

Page 4: ...S K3B601 α MPg DmXXX α L M R XXX 75 90 110cm In Mifare Card or Face Out Mifare Card DS K3B601 L M DmXXX DS K3B601 M M InPg DmXXX DS K3B601 R MPg DmXXX XXX 90 110cm NOTE 1 Select middle barrier according to channel quantity in customer side and select correct width for each channel according to the site If customer wants to use face recognition for verification please purchase DS K5603 Z face recog...

Page 5: ...emporary For iVMS 4200 software currently we use baseline V2 8 1 4 it s available from Hikvision official website https www hikvision com en Support Downloads Client Software 1 3 Parameters a Face picture capacity 10 000 DS K5603 Z 50 000 DS K5603T Z b Face recognition distance 0 3 m to 1 0 m c Person height 1 40 m 1 90 m d Import face picture through USB flash file name format must be same as bel...

Page 6: ...k with customer and site situation to confirm whether can trench on the ground for interconnect and network cables If not allowed please purchase base for barriers Standard scenario example 2 Ensure the ground is smooth so the IR transmitter and receiver on both side of barrier can work normally same as Figure 1 Figure 3 IR sensor on barriers Notes A The device should be installed on the concrete ...

Page 7: ...d 6 M12 screws 7 Bury interconnecting cables for pedestal communication Note For detailed information about burying and wiring interconnecting cables see Wiring Interconnecting Cable 8 According to the entrance and exit marks on the pedestals move the pedestals to the corresponded positions Note Make sure the installation holes on the pedestals and the base are aligned with each other 9 Secure the...

Page 8: ...ort Team 8 NOTE Power OFF before wiring to ensure safety 2 Connect master lane board and slave lane board through interconnecting cable the cable hole is in the bottom of barrier see Figure 5 Figure 5 Interconnecting Cable Hole 3 The ports on master and slave lane board are as below ...

Page 9: ...C power cord buried independently you should bury an AC power cord between the right pedestal and the central pedestal 4 If you want to bury both of the AC power cord and the low voltage cable at the entrance side the two cables should be in separated conduits to avoid interference 5 If all wires of the interconnecting cable have connected with peripherals and more peripherals are required to conn...

Page 10: ...make sure the pipe and the pedestal top panel are vertical 4 Secure hex socket screws a Rotate the pipe and align the four holes on the round panel with the holes on the pedestal top panel b Thread the supplied four M6 15 socket screws from up to down through the four holes respectively Do not tight up c Rotate the pipe and make sure the device display screen is in the correct direction d Tight th...

Page 11: ...the switch through UTP cable Note For face recognition terminal on master barrier we can connect network cable to switch direct but for the device on slave barrier it needs a network converter and an extension network cable then connect to the switch see figure 10 Figure 10 Terminals connected to switch 3 Configuration and Debug 3 1 Configure K3M200 barrier control board 1 Install iVMS 4200 client...

Page 12: ...which means enable study mode Adjust both side swing to correct position manually Then power on the barrier again and wait study process finish the barrier will open and close for one time 4 After device boot finish then power off the barrier and set No 1 dip switch to 0 normal mode and restart the barrier to take effect 3 2 Configure face recognition terminal 1 Activate device and set activation ...

Page 13: ... s frontal face with the format of JPEG or JPG c The face picture s resolution should be 640 480 or more The picture size should be between 60 KB and 200 KB d The pupillary distance of the face picture should be more than 60 pixel Enroll face picture from iVMS 4200 client software through USB camera model DS 2CS55D7B or import from PC local then sync to face recognition terminal Sync from Hikcentr...

Page 14: ...Face Recognition Swing Barrier Installation Guide_V1 1 20190215 docx Product Support Team 14 2 Add user info and card number 3 Add permission group and synchronize to device ...

Page 15: ...rd 3 One side barrier open normally but another side has some delay Solution Check barrier control board configuration and jumper position step 2 3 is correct Check RS232 cable and make sure cable is connected properly 4 After face verify successfully the barrier has no reaction or sometime cannot open Solution Check RS232 cable is connected properly ensure the cable is not connected opposite step...

Reviews: