EURO 280 Installation Manual
Page: 44
7 .
T h e I n o v o n i c s R a d i o E x p a n d e r
This radio expander is an 868 Inovonics receiver and programming PCB. It will connect to the panel via the D1, D2, D3,
and D4 terminals. NOTE: This expander will not work with the Enforcer wireless technology.
7.1
The Inovonics Radio Expander
The display is 2 x 7 segments and there are 4 control buttons:
‘AZ’
=
Assign zones/repeaters
‘MO’
=
EOL mode or iD mode (
Must be in EOL mode to use with Euro 280, ID no longer supported)
‘CLEAR’
= Clear
Information
‘ENTER’
= Accept
Information
A total of 7 detectors can be programmed using the End of Line mode on a radio expander.
The ‘
OK
’ and ‘
FAULT
’ LEDs relate to the RS485 connection to the EURO system.
NOTE
:
The last input on the expander should be programmed as ‘Fault’ with the name ‘RF Low Battery’ to indicate
a detector low battery problem. If an RF Low Battery is reported then the radio expander will show on the display
the number of the detector with the low battery: e.g. Lb…05.
Supervision failure will be reported as ‘tamper’ on the relevant input.
7.2
The Inovonics Radio PIR
Once the Radio PIR has seen an activation, it will then be inactive for four minutes. If the Radio PIR hasn’t seen any
activation within the four minutes, it will then be active again. This is to save the battery life of the detector.
7.3
Addressing the Radio Expander
Once a radio expander is installed on the system it must be enabled at the radio expander and the EURO control
panel. To perform this at the system you will need to go to ‘Install ZEM’, see the programming manual. To enable
this at the radio expander, follow the instructions below:
Hold down the ‘
ENTER
’ button until the mode and address are
displayed.
“E0”
= means End of Line mode, Address 0.
“I0”
= means iD mode, Address 0.
Press the
’MO’
button on the detector to toggle between End of
Line and iD modes.
MUST BE IN EOL MODE, ID NO LONGER SUPPORTED.
Press the
‘AZ’
button
to select the Wireless Input Expander
address number.
Press the
‘ENTER’
to confirm your selection.
D
1-
TX
R
ES
E
T
SE
R
IA
L
M
F
FA
D
2+
Vs
D
3
G
N
D
D
4
R
X
TAMPER
AZ
MO
CLEAR
ENTER
RESET
FAULT
8
8
ENTER
0
E
AZ
1
E