EURO 280 Installation Manual
Page: 24
6.3
Connecting the External Proximity Reader (EURO-PROXE - EURO-108X)
The External Proximity Reader can be used as either a
Set, Unset, Entry Control
or
Access Control
device.
NOTE:
See the reader installation manual for the LED and button explanations.
NOTE:
The total number of readers that can be installed on the EURO 280 is 7. The
readers are installed on the same bus as the keypads.
6.3.1
Technical Specification
EURO-108X (External Tag Reader)
Supply voltage:
9-15VDC
Current consumption:
Max 22mA
Input status when reader is Set/Unset or Ward Control:
Input:
Programmable. DEOL
Input EOL fixed resistor value:
Alarm=4K7 / Tamper=2K2
Normal: 1k4 to 2k9
Burglary Alarm:4k2 to 7k8
Tamper: <1k4 or >22k
Input status when reader is used as Access or Door Entry Control:
Input 1:
Programmable
Input Function:
Door monitor feature. Door opening time limit is programmable from the Engineer Menu
Input 2:
Not programmable
Note: Access control falls outside the scope of EN 50131
Output 1:
Not programmable. Activates the Door Lock Relay
Output 2:
Not programmable. Door monitor alarm activation (forced or open for longer than programmed
time).
Output 1/2 Normal state:
Floating
Output 1/2 Active state:
0V
Colour and Casing:
3mm ABS Black
Potted
Type B
Temperatures:
Storage: -10°C to 50°C
Certified: -25°C to 60°C
Nominal: -10°C to 50°C
Dimensions (H x W x D):
85 x 85 x 21mm
IP65 Rated. If the control panel fails to set, this is indicated by a broken tone on the external proximity reader and the red LED will not
illuminate. If this occurs, please check the information at the nearest keypad.
6.3.2
Addressing the External Tag Reader (From the Reader)