6
English
Table 1
Indications of the pilot lamp
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for
0.5 seconds. (o
ff
for 0.5 seconds)
While charging Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for
0.5 seconds. (o
ff
for 0.5 seconds)
Overheat
standby
Blinks
Lights for 1 second. Does not light for
0.5 seconds. (o
ff
for 0.5 seconds)
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Charging
impossible
Flickers
Lights for 0.1 seconds. Does not light for
0.1 seconds. (o
ff
for 0.1 seconds)
Malfunction in the
battery or the charger
●
Regarding the temperatures and charging time of the battery.
The temperatures and charging time will become as shown in
Table 2
Table 2
Charger
Battery
UC18YFSL
UC18YKSL
Charging voltage
V
14.4
–
18
Weight
kg
0.5
0.35
Temperatures at which the battery can be recharged
0
o
C
–
50
o
C
Charging time for battery capacity, approx.
(At 20
o
C)
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
6.0 Ah
8.0 Ah
min
min
min
min
min
min
min
min
22
30
35
45
60
75
90
120
40
60
75
90
120
150
180
240
Number of battery cells
4
–
10
○
When the pilot lamp
fl
ickers (at 0.2-second intervals),
check for and take out any foreign objects in the charger’s
battery connector. If there are no foreign objects, it is
probable that the battery or charger is malfunctioning.
Take it to your authorized Service Center.
○
Since the built-in micro computer takes about 3 seconds to
con
fi
rm that the battery being charged with charger is taken
out, wait for a minimum of 3 seconds before reinserting
it to continue charging. If the battery is reinserted within
3 seconds, the battery may not be properly charged.
○
If the pilot lamp does not blink in red (every
second) even though the charger cord is
connected to the power, it indicates that the
protection circuit of the charger may be activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the HiKOKI Authorized
Service Center.
NOTE
The recharging time may vary according to temperature
and power source voltage.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger
fi
rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
CAUTION
○
If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of the charger lights for 1 second, does not
light for 0.5 seconds (o
ff
for 0.5 seconds). In such a case,
fi
rst let the battery cool, then start charging.