17
English
2. Charger
Symptom
Possible cause
Remedy
The charge indicator lamp
is rapidly flickers purple,
and battery charging
doesn’t begin.
The battery is not inserted all the way.
Insert the battery firmly.
There is foreign matter in the battery
terminal or where the battery is attached.
Remove the foreign matter.
The charge indicator lamp
blinks red, and battery
charging doesn’t begin.
The battery is not inserted all the way.
Insert the battery firmly.
The battery is overheated.
If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Battery usage time is short
even though the battery is
fully charged.
The battery’s life is depleted.
Replace the battery with a new one.
The battery takes a long
time to charge.
The temperature of the battery, the charger,
or the surrounding environment is extremely
low.
Charge the battery indoors or in another
warmer environment.
The charger’s vents are blocked, causing its
internal components to overheat.
Avoid blocking the vents.
The cooling fan is not running.
Contact a HiKOKI Authorized Service
Center for repairs.
The USB power lamp
has switched off and the
USB device has stopped
charging.
The battery’s capacity has become low.
Replace the battery with one that has
capacity remaining.
Plug the charger’s power plug into an
electric socket.
USB power lamp does not
switch off even though the
USB device has finished
charging.
The USB power lamp lights up green to
indicate that USB charging is possible.
This is not a malfunction.
It is unclear what the
charging status of a USB
device is, or whether its
charging is complete.
The USB power lamp does not switch off
even when charging is complete.
Examine the USB device that is charging to
confirm its charging status.
Charging of a USB device
pauses midway.
The charger was plugged into an electrical
socket while the USB device was being
charged using the battery as the power
source.
This is not a malfunction.
The charger pauses USB charging for about
5 seconds when it is differentiating between
power sources.
A battery was inserted into the charger while
the USB device was being charged using a
power socket as the power source.
Charging of the USB device
pauses midway when the
battery and the USB device
are being charged at the
same time.
The battery has become fully charged.
This is not a malfunction.
The charger pauses USB charging for
about 5 seconds while it checks whether
the battery has successfully completed
charging.
Charging of the USB
device doesn’t start when
the battery and the USB
device are being charged
at the same time.
The remaining battery capacity is extremely
low.
This is not a malfunction.
When the battery capacity reaches a certain
level, USB charging automatically begins.
0000Book_CR36DA_EU.indb 17
2019/03/07 18:22:42
Summary of Contents for CR 36DA
Page 2: ...2 1 2 1 2 3 1 2 0000Book_CR36DA_EU indb 2 2019 03 07 18 22 33...
Page 3: ...3 4 Lm Mm Hm Maxm 0 0 1 2 1 2 5 1 2 3 6 0000Book_CR36DA_EU indb 3 2019 03 07 18 22 33...
Page 4: ...4 7 1 2 3 4 5 6 4 8 9 1 1 1 1 2 2 10 2 1 3 0000Book_CR36DA_EU indb 4 2019 03 07 18 22 35...
Page 5: ...5 11 12 13 14 15 0000Book_CR36DA_EU indb 5 2019 03 07 18 22 36...
Page 6: ...6 16 1 2 3 17 a b 18 19 2 1 2 1 0000Book_CR36DA_EU indb 6 2019 03 07 18 22 37...
Page 150: ...150 HiKOKI 1 5 0000Book_CR36DA_EU indb 150 2019 03 07 18 23 31...
Page 248: ...248 HiKOKI 1 5 0000Book_CR36DA_EU indb 248 2019 03 07 18 24 09...
Page 276: ...276 0000Book_CR36DA_EU indb 276 2019 03 07 18 24 20...
Page 278: ...278 0000Book_CR36DA_EU indb 278 2019 03 07 18 24 23...
Page 280: ...280 0000Book_CR36DA_EU indb 280 2019 03 07 18 24 23...
Page 281: ...281 0000Book_CR36DA_EU indb 281 2019 03 07 18 24 23...