background image

Handheld Thermography Camera User Manual 

viii 

Symbol Conventions 

The symbols that may be found in this document are defined as follows. 

 

Symbol 

Description 

Danger 

 

Indicates a hazardous situation which, if not 
avoided, will or could result in death or serious 
injury. 

Caution 

 

Indicates a potentially hazardous situation which, if 
not avoided, could result in equipment damage, 
data loss, performance degradation, or unexpected 
results. 

Note 

 

Provides additional information to emphasize or 
supplement important points of the main text. 

  

Summary of Contents for Pocket Series

Page 1: ...Handheld Thermography Camera HIKMICRO Pocket Series User Manual ...

Page 2: ...MICRO s trademarks and logos are the properties of HIKMICRO in various jurisdictions Other trademarks and logos mentioned are the properties of their respective owners Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS MANUAL AND THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS HIKMICRO MAKES NO WARRANTIES EXPRESS OR IMP...

Page 3: ...IN COMPLIANCE WITH ALL APPLICABLE LAWS AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW ESPECIALLY YOU ARE RESPONSIBLE FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES INCLUDING WITHOUT LIMITATION RIGHTS OF PUBLICITY INTELLECTUAL PROPERTY RIGHTS OR DATA PROTECTION AND OTHER PRIVACY RIGHTS YOU SHALL NOT USE THIS PRODUCT...

Page 4: ...rence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connec...

Page 5: ... when operating in the 5150 to 5350 MHz frequency range this device is restricted to indoor use in Austria AT Belgium BE Bulgaria BG Croatia HR Cyprus CY the Czech Republic CZ Denmark DK Estonia EE Finland FI France FR Germany DE Greece EL Hungary HU Iceland IS Ireland IE Italy IT Latvia LV Liechtenstein LI Lithuania LT Luxembourg LU Malta MT Netherlands NL Northern Ireland UK NI Norway NO Poland ...

Page 6: ...ith this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to your supplier or to a designated collection point For more information see www recyclethis info Industry Canada ICES 003 Compliance This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this devi...

Page 7: ...riate i Les dispositifs fonctionnant dans la bande 5150 5250 MHz sont réservés uniquement pour une utilisation à l intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux ii Le gain d antenne maximal autorisé pour les appareils dans les bandes 5250 5350 MHz et 5470 5725 MHz doivent respecter le pire limiter et iii Le gain d an...

Page 8: ...mography Camera User Manual vii et 5650 5850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL KC B급 기기 이 기기는 가정용 B급 전자파적합기기로써 주로 가정에서 사용하는 것을 목적으로 하며 모든 지역에서 사용할 수 있습니다 ...

Page 9: ... Indicates a hazardous situation which if not avoided will or could result in death or serious injury Caution Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance degradation or unexpected results Note Provides additional information to emphasize or supplement important points of the main text ...

Page 10: ...shall not take any responsibilities DO NOT drop the product or subject it to physical shock Keep the device away from magnetic interference Power Supply Input voltage should meet the Limited Power Source 3 85 VDC 570 mA according to the IEC62368 standard Please refer to technical specifications for detailed information Make sure the plug is properly connected to the power socket DO NOT connect mul...

Page 11: ...n the reach of children When the device is powered off and the RTC battery is full the time settings can be kept for 6 months In the first use charge the device for more than 2 5 hours in the power off status The lithium battery voltage is 3 85 V and the battery capacity is 2100 mAh The battery is certified by UL2054 Maintenance If the product does not work properly please contact your dealer or t...

Page 12: ...alibration once a year and please contact the local dealer for the information on maintenance points For more detailed calibration services please refer to https www hikmicrotech com en calibrationservices 2 Using Environment Make sure the running environment meets the requirement of the device The operating temperature shall be 10 C to 50 C 14 F to 122 F and the operating humidity shall be 95 or ...

Page 13: ...ufacture Address Room 313 Unit B Building 2 399 Danfeng Road Xixing Subdistrict Binjiang District Hangzhou Zhejiang 310052 China Hangzhou Microimage Software Co Ltd COMPLIANCE NOTICE The thermal series products might be subject to export controls in various countries or regions including without limitation the United States European Union United Kingdom and or other member countries of the Wassena...

Page 14: ... 2 1 Set Auto Power off Duration 5 2 3 Operation Method 6 2 4 Menu Description 6 Chapter 3 Display Settings 7 3 1 Set Screen Brightness 7 3 2 Set Display Mode 7 3 3 Set Palettes 8 3 4 Adjust Digital Zoom 9 3 5 Display OSD Info 10 Chapter 4 Temperature Measurement 11 4 1 Set Thermography Parameters 11 4 1 1 Set Unit 12 4 2 Set Level Span 12 4 3 Set Thermography Rule 13 4 4 Set Temperature Alarm 13 ...

Page 15: ... View Recorded Files 18 5 5 Manage Files 19 5 5 1 Delete a File 19 5 5 2 Delete Multiple Files 19 5 5 3 Move a File 20 5 5 4 Move Multiple Files 20 5 5 5 Add Text Note on File 20 5 6 Export Files 21 Chapter 6 Connect Bluetooth 22 Chapter 7 Set LED Light 23 Chapter 8 Cast Screen 24 Chapter 9 Set Macro Mode 25 Chapter 10 Thermal View APP Connection 26 10 1 Connect via Wi Fi 26 10 2 Connect via Hotsp...

Page 16: ...ra User Manual xv 11 2 Set Date and Time 29 11 3 Upgrade Device 29 11 4 Restore Device 30 Chapter 12 Appendix 31 12 1 Common Material Emissivity Reference 31 12 2 Device Command 31 12 3 Device Communication Matrix 32 12 4 FAQ 32 ...

Page 17: ...ith the accuracy of 2 C 3 6 F or 2 when the ambient temperature is 15 C to 35 C 59 F to 95 F and the object temperature is above 0 C 32 F The device is easy to use and adopts ergonomic design It is widely used for building inspection HVAC as well as electrical and mechanical equipment maintenance Main Function Thermography Device detects the real time temperature and display it on the screen Fusio...

Page 18: ...nload the App HIKMICRO Viewer Android HIKMICRO Viewer iOS PC You can download HIKMICRO Analyzer https www hikmicrotech com en product c detail 18 to analyze pictures offline professionally and generate a custom format report on your PC Bluetooth Device can be connected to headset via Bluetooth and you can hear the voice in the recording 1 3 Appearance ...

Page 19: ...File Key Tap to enter albums 3 Settings Key Tap to enter settings interface 4 Flash Light Fill light on objects and output flashing alarm 5 Thermal Lens View the thermal image 6 Optical Lens View the optical image 7 Power Key Hold to power on off the device 8 Capture Key Press in live view mode capture snapshots stop recording Press in menu mode return to the live view interface Hold start recordi...

Page 20: ...Type C Interface Charge the device or export files with Type C cable 13 Buzzer Output audible alarm Note Your camera will periodically perform a self calibration to optimize image quality and measurement accuracy In this process the image will pause briefly and you ll hear a click as a shutter moves in front of the detector The self calibration will be more frequent during start up or in very cold...

Page 21: ...the battery 2 2 Power On Off Power On Hold for over three seconds to turn on the device You can observe the target when the interface of the device is stable Note It may take at least 30 s until the device is ready for using when you power on it Power Off When the device is turned on hold for about three seconds to power off the device 2 2 1 Set Auto Power off Duration Go to Local Settings Device ...

Page 22: ... You can tap the screen to set parameters and configurations 2 4 Menu Description In the observation interface tap the screen to show the menu bar and swipe down to call the swipe down menu Home File Settings Menu Figure 2 1 Main Menu Wi Fi Bluetooth Hotspot Screen Cast Flashlight Dark Bright Mode Figure 2 2 Swipe Down Menu ...

Page 23: ...Figure 3 1 Adjust Brightness via Swipe Down Menu 3 2 Set Display Mode You can set the thermal optical view of the device Thermal Fusion PIP and Optical are selectable Steps 1 Tap Menu and select 2 Tap the icons to select a view mode In thermal mode the device displays the thermal view In fusion mode the device displays the combined view of thermal channel and optical channel ...

Page 24: ... better overlap the thermal and optical images Figure 3 2 Adjust Parallax Correction In PIP Picture in Picture mode the device displays thermal view inside the optical view Note You can adjust the size distance and digital zoom of the PIP In optical mode the device displays the optical view 3 Press Back to exit 3 3 Set Palettes The palettes allow you to select the desired colors Steps 1 Tap Menu a...

Page 25: ...ble for scene without obvious temperature difference Ironbow The target is colored as heated iron Red Hot The hot part is red colored in view Fusion The hot part is yellow colored and the cold part is purple colored in view Rain The hot part in the image are colored and the else is blue 3 Press Back to exit the setting interface 3 4 Adjust Digital Zoom Steps 1 Tap the live view interface to call t...

Page 26: ...en to save and exit 3 5 Display OSD Info Go to Local Settings Device Settings Display Settings to enable the information on screen display Time Device time and date Parameters Thermography parameters for example target emissivity temperature unit etc Brand Logo The brand logo is a manufacturer logo displayed on the upper right corner of the screen ...

Page 27: ...the Thermography Range Emissivity etc Thermography Range Select the temperature measurement range The device can detect the temperature and switch thermography range automatically in Auto Switch mode Emissivity Refer to Common Material Emissivity Reference to set the emissivity of your target Reflection Temperature If any object not the target of high temperature is in the scene and the target emi...

Page 28: ...the temperature range with the Level Span function Set a temperature section and the palette only works for targets within the temperature section The Level Span can be manually or automatically adjusted to achieve a good thermal effect for better temperature difference analysis Steps 1 Tap Menu and select 2 Select auto adjustment or manual adjustment Auto Adjustment Select The device adjusts temp...

Page 29: ...ture value 3 Press Back to exit 4 3 Set Thermography Rule You can set thermography rules to measure the min max and center temperatures of the current scene Steps 1 Tap Menu and select 2 Tap to select the thermography rule as required Hot Cold and Center are selectable 3 Tap Back to save and exit Note The min max and center temperatures are displayed on the left top of the screen Tap the rule agai...

Page 30: ...e client software It if the audible warning is enabled and the flashlight will flash if the flashing alarm is enabled Alert Threshold When the tested temperature exceeds the threshold the device sends alert notification to the client software 3 Go to Local Settings Thermography Settings Alarm Settings Alarm Linkage 4 Enable Audible Warning Flash Alarm or both Audible Warning The device triggers vo...

Page 31: ...g or recording to distinguish the files recorded in a specify scene 5 1 Capture Picture Before You Start Enable the flashlight via the swipe down menu in dark environment Steps 1 Go to Local Settings Capture Settings 2 Select Photo Settings to set the capture mode Single Capture Capture one picture for one time Continuous Capture Capture multiple pictures for one time You can set the amount of pic...

Page 32: ... key to start recording The recording icon and count down number display in the interface Figure 5 1 Record Video 2 When you finish press the capture key to stop recording The recording video will be saved automatically 3 Refer to Export Files to export the snapshots 5 3 Manage Albums The recorded image video files are saved in the albums You can create new folders rename a folder change the defau...

Page 33: ...appears at the top of the album list 5 3 2 Rename an Album Steps 1 Press to enter Albums 2 Select the album to rename 3 Tap and select Rename A soft keyboard is displayed 4 Tap to delete the old name and enter the new name for the album by touching the screen 5 Tap to finish 5 3 3 Change the Default Saving Album Steps 1 Press to enter Albums 2 Select the album you want to use as the default saving...

Page 34: ...ears on the interface 4 Tap OK to delete the album 5 4 View Recorded Files Steps 1 Press to enter Albums 2 Tap to select the album storing the files 3 Tap to select the video or snapshot to view 4 View the selected file and relevant information Figure 5 2 View a File Note For more information contained in capture snapshots or videos you can install the thermography client to analyze them ...

Page 35: ...album tap to select the file to be deleted 4 Tap and select Delete A prompt box appears on the interface 5 Tap OK to delete the file 5 5 2 Delete Multiple Files Steps 1 Press to enter Albums 2 Tap to select the album storing the files to be deleted 3 In the album tap and tap the files to be deleted Note You can tap to select all files and tap to cancel the selection 4 Tap A prompt box appears on t...

Page 36: ...ap to select the album storing the files to be moved 3 In the album tap to select the files to be moved Note You can tap to select all files and tap to cancel the selection 4 Tap The album list is displayed 5 Tap to select the album to move to Note You can also move a single file in this way 5 5 5 Add Text Note on File Steps 1 Press to enter Albums 2 Tap to select the album storing the file to be ...

Page 37: ...o your PC with supplied cable you can export the recorded videos and captured snapshots Steps 1 Open the cover of cable interface 2 Connect the device to your PC with cable and open the detected disk 3 Select and copy the videos or snapshots to PC to view the files 4 Disconnect the device from your PC Note For the first time connection the driver will be installed automatically ...

Page 38: ...e with bluetooth headsets successfully Steps 1 Select from the main menu 2 Go to Local Settings Connect Bluetooth 3 Tap to enable the bluetooth Note You can also press to quit pairing The device will search the nearby enabled bluetooth headsets and pair them automatically Result After pairing you can record and hear the sound via the headsets while recording and playing the video or image ...

Page 39: ...Handheld Thermography Camera Pocket Series User Manual 23 Chapter 7 Set LED Light Tap the flashlight button on the swipe down menu to enable the LED light ...

Page 40: ...the distance and the emissivity on your PC Before You Start Download the UVC Alarm Client from HIKMICRO official website and install the client on your PC Refer to the user manual of the client for detailed operation Steps 1 Select from the main menu 2 Go to Local Settings Connect Cast Screen 3 Tap to enable the function 4 Open UVC Alarm Client on your PC 4 Connect the device to your PC via a type...

Page 41: ...s for detailed operation The macro lens is not included in the package Please purchase it separately The recommended model is HM P201 MACRO Steps 1 Select from the main menu 2 Go to Local Settings Capture Settings Macro Mode 3 Tap to enable the function Note After the macro mode is enabled only the emissivity can be modified Parameters such as distance image mode parallax correction and measuremen...

Page 42: ...client 10 1 Connect via Wi Fi Before You Start Download and install HIKMICRO Viewer on your phone Steps 1 Select from the main menu 2 Go to Local Settings Connect WLAN 3 Tap to enable Wi Fi and the searched Wi Fi will be listed Figure 9 1 Wi Fi List 4 Select the Wi Fi to connect to A soft keyboard is displayed 5 Enter the password by touching the screen Note DO NOT tap enter or space or the passwo...

Page 43: ...via the App 10 2 Connect via Hotspot Before You Start Download and install HIKMICRO Viewer on your phone Steps 1 Select from the main menu 2 Go to Local Settings Connect Hotspot 2 Tap to enable the hotspot function The hotspot name is the last 9 digits of the device serial No 3 Tap Set Hot Spot A soft keyboard is displayed Figure 9 2 Set Hotspot 4 Set the password for the hotspot Note DO NOT tap e...

Page 44: ... 6 Connect your phone to the hotspot of the device 7 Launch the App and follow the startup wizard to create and register an account 8 Select Wi Fi configuration in the App and enter the serial number of device to add the device Refer to the manual of APP client for details Result You can view the live view capture snapshots and record videos via the App ...

Page 45: ...the date and time 3 Press to save and exit Note Go to Local Settings Device Settings Display Settings to enable or disable time and date display 11 3 Upgrade Device Steps 1 Connect the device to your PC with cable and open the detected disk 2 Copy the upgrade file and paste it to the root directory of the device 3 Disconnect the device from your PC 4 Reboot the device and then it will upgrade auto...

Page 46: ...fter upgrading the device reboots automatically You can view the current version in Local Settings Device Settings Device Information 11 4 Restore Device Go to Local Settings Device Settings Device Initialization to initialize the device and restore default settings ...

Page 47: ...n 0 98 Printed Circuit Board 0 91 Concrete 0 95 Ceramic 0 92 Rubber 0 95 Paint 0 93 Wood 0 85 Pitch 0 96 Brick 0 95 Sand 0 90 Soil 0 92 Cloth 0 98 Hard Paperboard 0 90 White Paper 0 90 Water 0 96 12 2 Device Command Scan the following QR code to get device common serial port commands Note that the command list contains the commonly used serial port ...

Page 48: ... for HIKMICRO thermal cameras 12 3 Device Communication Matrix Scan the following QR code to get device communication matrix Note that the matrix contains all communication ports of HIKMICRO thermal cameras 12 4 FAQ Scan the following QR code to get device common FAQ ...

Page 49: ...Facebook HIKMICRO Thermography LinkedIn HIKMICRO Instagram hikmicro_thermography YouTube HIKMICRO Thermography E mail info hikmicrotech com Website https www hikmicrotech com UD29202B ...

Reviews: