14
alarm, and sending notification to the client software.
Steps
1. Go to Local Settings → Thermography Settings → Alarm Settings →
Temperature Alarm.
2. Enable the function and set the alarm threshold and alert threshold.
Alarm Threshold
When the tested temperature exceeds the threshold, the device
sends alarm notification to the client software. It if the audible
warning is enabled, and the flashlight will flash if the flashing alarm is
enabled.
Alert Threshold
When the tested temperature exceeds the threshold, the device
sends alert notification to the client software.
3. Go to Local Settings → Thermography Settings → Alarm Settings →
Alarm Linkage.
4. Enable Audible Warning, Flash Alarm, or both.
Audible Warning
The device triggers voice alarm when target temperature exceeds the
alarm threshold.
Flash Alarm
The flashlight will flash when target temperature exceeds the alarm
threshold.
4. Tap to save and exit.