16
ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician following the normal regulations.
Protection against the parts under tension must be ensured after the building-in.
The information on connections necessary are on the stickers. Place them on the hob
casing near the connection box.
Connection to the mains must be made using an earthed plug, which must be accessible
after installation, or via an omnipolar circuit breaking device with a contact opening of at
least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
If the appliance is not fitted with an accessible plug, a disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance must only be connected to a 230 V~ 50/60 Hz network.
Connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover.
CONNECTION OF THE HOB FOR HT3IFC-2
* minimum cable thermal rating: 90°C
CONNECTION OF THE HOB FOR HP4IFC-2
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
5 x 1.5 mm²
H 05 V2V2
– F*
40 A
400V~ 50/60Hz
2 N
5 x 1.5 mm²
H 05 V2V2
– F*
25 A
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
Summary of Contents for HP4IFC-2
Page 1: ...USE AND CARE INDUCTION COOKTOPS HP4IFC 2 HP6IFC 2 HT3IFC 2 ...
Page 2: ......
Page 18: ......
Page 19: ......
Page 20: ...17394 0 ...