Connect the lightning protector
A08
on the gateway connector
A15
.
1.
Connect the other end of the LoRa antenna cable
A07
to field LoRa
antenna
B01
.
4.
Connect the lightning protector to a grounding point using a grounding
cable (not provided)*.
2.
Connect the LoRa antenna cable
A07
to the lighting protector
A08
.
3.
SECTION 03
Grounding the Hiberband Via gateway and BGAN terminal to an electrical
earth connection is strongly advised, especially where the LoRa antenna and/
or the Hiberband Via gateway and BGAN terminal are placed higher than
surrounding objects. If an electrical earth connection isn’t available, connect
to a large conducting surface like a metal beam which is connected to earth.
Consult a qualified electrician if in doubt.
*
Connect the Wi-Fi antenna
A06
to the Via gateway connector
A14
.
5.
Connect the blue BGAN ethernet cable
C02
to Via gateway connector
A16
.
6.
Connect the black BGAN power cable
C03
to Via gateway connector
A17
.
7.
A08
A15
FIG. 08.1
FIG. 08.2
A07
FIG. 08.3