Total Station Manual
-
29 -
press
:
1013hPa
temperature
:
20
℃
If the atmospheric correction is not required, please set PPM to zero.
Steps
Key
Display
○
1 After entering to the
interface of EDM Setting.
Press [F1] (Atoms) to enter
the interface of Atomspheric
Data.
[F1]
[EDM Setting]
EDM Mode:
Reflector: Prism
P.C. : 30.0 mm
OK
Single
ATOMS Pointer
○
2
Interface displays the
current settings.
↓
[Atomspheric Data]
Temp. :
Press :
PPM :
Refraction
OK
20 ℃
1013 hPa
5.6 PPM
0.00
PPM=0
○
3
Input the value of
temperature.
example
:
Enter 26
℃
and
press the key of [ENT].
The cursor moves to the
setting item of Press.
[ENT]
[Atomspheric Data]
Temp. :
Press :
PPM :
Refraction
OK
26 ℃
1013 hPa
5.6 PPM
0.00
PPM=0
○
4 Input the value of
atmospheric pressure.
example
:
Enter 1020 hPa and
press the key of[ENT].Program
calculates the value of PPM
and the cursor moves to the
setting item of PPM.
※
1
※
2
※
3
※
4
[ENT]
[Atomspheric Data]
Temp. :
Press :
PPM :
Refraction
OK
26 ℃
1020 hPa
3.7 PPM
0.00
PPM=0