d) Connect the power cords and cables to the enclosure.
Figure 22: Standard Power Cord and Cable Connections
e) Close all of the baskets.
f) Reconnect the CMA at the elbow to connector A.
8.
Test for binding in the extension of the CMA by gently pulling the enclosure out of the rack to ensure the
cables extend properly and that the system doesn’t bind at all. If it does, examine the point at which the
binding occurred and adjust the seating of cables in the baskets, check the connections to the rails, and
examine the joints of the CMA arm to ensure that they are all functioning properly.
9.
Make sure the CMA is in operational position by folding the arm in toward the enclosure and attaching
the elbow end of the CMA to the connector that is attached to the rail.
10. Secure the rack ear shipping screws.
a) Locate the rack ear covers.
Figure 23: Rack Ear Shipping Screw Covers
29
4
Installation
Installation Guide
4.2
Ultrastar Serv24 Installation Procedure