Operational
Non-Operational
Specification
950m to 3048m
950m to 12000m
Altitude
Table 2: Electrical Specifications
Value
Specification
1000W (low line) / 1200W (high line)
Maximum Power Consumption
100-127VAC (low line) / 200-240VAC (high line)
Input Voltage
C14
PSU Connector Type
AC line inrush current shall not exceed 30A peak,
for up to one-quarter of the AC cycle, after which,
Inrush Current Maximum (per PSU)
the input current should be no more than the
specified maximum input current.
80 Plus
™
Platinum
PSU Efficiency
Table 3: Mechanical Specifications
Operational
Non-Operational
Specification
10G - 5 ms duration; 5 shocks
positive and 5 negative in each of
3 axes. 30 total shocks
35G - 152 in/sec trapezoid wave
Shock
0.278G - Random 5-500 Hz 30
minutes per axis, 3 axes (X, Y, Z)
1.04G - 2~200Hz, 15
minutes/faces, six product faces
Vibration
33.47 kg / 73.8 lbs
Weight
39.23 kg / 86.5 lbs
Weight w/ Rails and CMA
W: 481.8 mm x L: 768.2 mm x H: 87 mm / W: 18.8in. x L: 30.2in. x
H: 3.4in.
Dimensions
W: 481.8 mm x L: 1021.3 mm x H: 87 mm / W: 18.8in. x L: 40.2in. x
H: 3.4in.
Dimensions w/ CMA
796.2 mm / 31.3in.
Rack Mounted Rails Travel
Note: Measured from the rack posts to the front of the
enclosure.
482.6 mm / 19 in.
Required Rack Width
See EIA-310 Rack Standard
Required Rack Depth
12
1
Ultrastar Serv24 Overview
Installation Guide
1.3
Ultrastar Serv24 Specification Summary