![HGI Generators HRD270T1 Operation And Maintenance Manual Download Page 8](http://html1.mh-extra.com/html/hgi-generators/hrd270t1/hrd270t1_operation-and-maintenance-manual_2128487008.webp)
Harrington Generators International
3
HRD Diesel Generator
498-1052
Certi
fi
cation
Data Plate
Each generator supplied will have a data plate attached to the canopy of the set. Below is an exemplar data
plate with notes to help understand the terminology and information supplied on the data plate of your machine.
Harrington Generators International Ltd
Ravenstor Road Wirksworth Derbyshire, DE4 4FY
Tel: +44(0)1629 824284 Fax +44(0)1629 824613
www.hgigenerators.com [email protected]
Generating Set ISO 8528 COP Class G2
Model:
HRD Serial No: 70366893
Build Code:
HRD270T1 Year of Manufacture:
2014
Electrical Power:
27.0kVA / 21.6kW
PF:
0.8 Frequency:
50 Hz
Voltage Volts:
400V
230V
110V
Current Amps:
39
78
84
Max Altitude:
1500m Max Ambient Temperature:
40
°
C
Weight Fuel Tank Empty / Full:
902/1026 kgs
Fuel:
Diesel
Engine Speed:
1500 rpm
Sound Level
LwA 88 dB(A)
This is the “CE” mark and indicates that the generator complies
with the European Directives as detailed in the Certi
fi
cate of
Conformance
Model:
This is the build model of the machine e.g. Silent Knight
Build Code:
This is a code number, which tells us the exact build standard to
which the generator was built. This is important when ordering
spares or contacting our Technical Help Line
Serial No:
This is a unique number, which identi
fi
es the generator. This is
important when ordering spares or contacting our Technical Help
Line
Year of Manufacture:
Year of Manufacture e.g. 2013
Electrical Power:
This is the power in kVA and kW, the power factor and frequency
Voltage:
This is the nominal voltage e.g. 400V, 230V or 110V
Current Amps:
This is the nominal electrical current of the principal voltage
Performance Class
G2 provides steady state voltage deviation ± 2.5% for use with
standard electronic equipment.
Sound Pressure Level:
This is the level of sound produced by the generator when running at
75% auxiliary power. This generator complies with the CE Directive
on sound levels
Maximum Altitude /
Ambient Temperature:
These are given and if the generator is to be used at higher altitudes
or at higher ambient temperatures HGI should be consulted
Weight:
This provides weights including and excluding a full tank of fuel
Fuel:
Only commercially available diesel fuel can be used. If a special
type of diesel is to be used please consult HGI
fi
rst to discuss its
suitability