![Heylo KT 1800 User Manual Download Page 19](http://html1.mh-extra.com/html/heylo/kt-1800/kt-1800_user-manual_2128340019.webp)
19
EN
3 PURGE (EMPTYING)
Press the button purge (3) to get the emptying mechanism going before tilting the device. Water will
be emptied from the water container of the pump in this way to prevent leakage. After switching off the
device, with the plug inserted, wait for about 10 minutes so that the entire remaining water can run into
the pump's water container. Next, press EMPTY to remove the remaining water. Emptying takes place
automatically during operation every six minutes and/or if the water container is full. The display
indicates PUMP IS EMPTYING during the emptying process.
4 CLEAR (DELETE)
First press the DISPLAY button (2) to delete the INSTRUCTED HOURS, so that the uninterrupted
INSTRUCTION-H indicator appears on the display. Then press the DELETE button (4) to re-set the
counter to 00000. PLEASE NOTE: The TOTAL HOURS display cannot be set to 00000.
Automatic thawing (de-frosting on)
The display always shows DE-FROSTING ON when the device is running through a de-frosting cycle.
During normal operation, ice that forms on the lines is detected by the temperature sensor and the de-
frosting cycle is set into motion. The de-humidifying process is interrupted while hot gas flows through
the line and the ice melts. The display returns to the normal indicator at the end of the de-frosting
cycle.
KW/h counter
The KW/h counter shows you the total status of used energy.
Please note the counter status before starting the job.
The red light on the counter shows you that usage is being measured.
The counter is counting 0.001 KW/h per blink impulse.
Error display
If there are errors or interferences during operation, an error message "
SERVICE ERROR"
appears
on the display followed by "
ER01"
or another error number. Please follow these Stepps (see point 9
operation display):
1.
Pull the device plug from the mains and plug it back in again. The electronics will re-set itself.
2.
If the problem is not solved by doing this, see the following solutions according to the table.
3.
If the problem is still not solved, contact the HEYLO Service Department.
ER
1-2-3-5-6
Problem with the electronic operating field. Inform the HEYLO service
department.
ER4
Problem with the temperature sensor or the cable.
ER8
Problem with a sensor control button. Press and release each button several
times.
ER9
Check for blockages in the pump or drainage hose and ensure that the pump
is connected properly.