Heylo KT 1800 User Manual Download Page 18

18

EN

3

6.

Hang the pump drainage hose in a sink, toilet, drain or bucket. Unwind the hose completely to
avoid buckling due to very tight winding up. Make sure that the end of the condensate hose is in a
drain or condensate container and cannot slip out during operation.
Make sure that any condensate container you use can hold the required amount. The

KT 1800

can dehumidify up to 55 L in 24 hours.

7.

Water must be emptied from the pump before the device is moved. Turn the device OFF for 10
minutes for this purpose, so that the water runs from the cooling lines into the pump. Then press
the PURGE (emptying) switch (3).

8.

CAUTION: Check that the dehumidifier is functioning properly daily. Protect the floors from any
water that could possibly leak out.

9.

Functions of the sensor control

The  sensor  control  of  the  dehumidifier  indicates  a  display  and  four  buttons.  The  normal
displays are:

DE-HUMIDIFIER OFF

KMPRSR VERZ. 60

DE-HUMIDIFIER ON

PUMP EMPTIES

TOTAL-H=00000

DE-FROST ON

INSTRUCTION-H=00000

SERVICE ERROR 01

Operating buttons of the sensor control

1  ON-OFF

After connecting the device for the first time, the display runs through the following three indicators:
DE-HUMIDIFIER OFF
TOTAL NUMBER OF HOURS
HOURS INSTRUCTED.

Press the ON-OFF (1) button to switch on the device. The display often shows KMPRSR VERZ. 60
and counts backwards from a maximum of 60 to 0 seconds.
Next, the device is automatically run and the display shows DE-HUMIDIFIER ON.
(The delay prevents damages as a consequence of coincidental power interruption by switching the
compressor on and off, if the pressure in the system is still too high.)

2  DISPLAY

Press the Display button (2) to hold the display at DE-HUMIDIFIER ON or OFF, TOTAL NO. OF
HOURS or INSTRUCTED HOURS when running. Pressing again will run the display again.

2

1

4

Summary of Contents for KT 1800

Page 1: ...www heylo de Stand 06 2016 Art Nr 1 110 670 KT 1800 KONDENSATIONSTROCKNER BEDIENUNGSANLEITUNG USER MANUEL DE Kondensationstrockner EN Condensation dryer DER EXPERTE F R PROFIS...

Page 2: ...Vertr glichkeit EMC Part 6 3 EN 61000 6 1 2007 Elektromagnetische Vertr glichkeit EMC Part 6 1 EN 61000 6 2 2006 Elektromagnetische Vertr glichkeit EMC EN 61000 6 3 2008 Elektromagnetische Vertr glich...

Page 3: ...Verschmutzungen in den Kondensationstrockner gesaugt werden Reparaturen des Ger tes Bitte lassen Sie Reparaturarbeiten nur von Servicepartnern der Firma HEYLO durchf hren Informationen ber zugelassen...

Page 4: ...HEYLO DriEaz Kondensationstrockner erw rmt die Luft der er die Feuchtigkeit entzieht In kleineren R umen kann dadurch die Temperatur betr chtlich ansteigen Zimmertemperaturen zwischen 20 und 27 C bie...

Page 5: ...tschlauchs in einen Abfluss oder Kondensatbeh lter befindet und nicht w hrend des Betriebs herausrutschen kann Achten Sie darauf dass ein eventueller Kondensatbeh lter genug Fassungsverm gen hat Der K...

Page 6: ...ckgebliebene Wasser zu entfernen Das Leeren erfolgt w hrend des Betriebes automatisch alle sechs Minuten und oder wenn der Wasserbeh lter voll ist W hrend des Leervorgangs zeigt das Display PUMPE LEE...

Page 7: ...t Wasser und einem milden Reinigungsmittel auszuwaschen und vor dem erneuten Einsatz zu trocknen Bei Verwendung gefalteter Papierfilter ist der verunreinigte Filter zu entsorgen und ein neuer einzuset...

Page 8: ...a e 830 x 500 x 500 mm Betriebsbereich 1 38 C Filter Schaumstoff oder Papier Entfrostung Abtauautomatik Hei gas Pumpe Zentrifugal Kondensatpumpen F rderh he 6 1 m K hlmittel R 410A g 369 Hochdruck 16...

Page 9: ...HEYLO Turbotrocknern erh hen Luftfluss in den zu trocknenden Bereichen reduzieren Eis oder Feuchtigkeit nur An einem Teil der K hl schlangen System m glicherweise undicht Geringe F llung des Systems H...

Page 10: ...10 DE 9 Ersatzteilliste...

Page 11: ...11 DE...

Page 12: ...0813 Schlauchbefestigung 11 Nylon 93 DE13 00083 Tubing 3 8 x 5 8 OD Braided Pvc 35 52 1306000 Kondensatf rderpumpe 99 DE18 01052 Anschlu st ck mit Reduzierung 3 8 x 1 4 20 21 DE03 00121 Dichtung 1 2 x...

Page 13: ...1306016 Filtereinsatz f r Ersatzfilter 1110802 ACE Ventilator f r bessere Trocknungsleistung 1430047 Hydrostat f r Steckdosenbetrieb 10 90 r h 1250076 Luftschlauch KT1800 3m Wenden Sie sich f r Ersatz...

Page 14: ...14 DE 10 Schaltplan...

Page 15: ...00 6 3 2007 Electro Magnetic Compatibility EMC part 6 3 EN 61000 6 1 2007 Electro Magnetic Compatibility EMC part 6 1 EN 61000 6 2 2006 Electro Magnetic Compatibility EMC EN 61000 6 3 2008 Electro Mag...

Page 16: ...ut of the room through a cold humidification line The moisture condenses on the line drips off and is then removed through the condensation conveying pump and the drainage hose The now warmer and drie...

Page 17: ...er language 1 Pull out the plug from the mains 2 Keep the DISPLAY button 2 pressed down while connecting the device to the mains power supply The display now shows ENGLISH 3 Press the DISPLAY button o...

Page 18: ...rol of the dehumidifier indicates a display and four buttons The normal displays are DE HUMIDIFIER OFF KMPRSR VERZ 60 DE HUMIDIFIER ON PUMP EMPTIES TOTAL H 00000 DE FROST ON INSTRUCTION H 00000 SERVIC...

Page 19: ...frosting cycle is set into motion The de humidifying process is interrupted while hot gas flows through the line and the ice melts The display returns to the normal indicator at the end of the de fros...

Page 20: ...ling lines A cannot remove the water efficiently Check them regularly particularly when operating in dusty surrounding The lines must be dry for this purpose At this point they should be cleaned with...

Page 21: ...ensions 830 x 500 x 500 mm Operating area 1 38 C Filters Plastic or paper De frosting Automatic thawing hot gas Pump Centrifugal Condensate pumps conveying height 6 1 m Coolant R 410A 369 g High press...

Page 22: ...ovement with HEYLO turbo dryers Reduce air flow in the areas to be dried Ice or moisture only on one part of the cooling line System is possibly leaking System is not filled enough HS HS Look for leak...

Page 23: ...23 EN 9 Spare parts list...

Page 24: ...24 EN...

Page 25: ...ent 11 Nylon 93 DE13 00083 Tubing 3 8 x 5 8 OD Braided Pvc 35 52 1306000 Condensate conveying pump 99 DE18 01052 Connecting piece with reduction 3 8 x 1 4 20 21 DE03 00121 Gasket 1 2 x 1 2 Polyurethan...

Page 26: ...r material 1306016 Filter insert for spare filter 1110802 ACE Ventilator for better drying performance 1430047 Hydrostat for socket operation 10 90 r h 1250076 Air hose KT1800 3m Contact your local de...

Page 27: ...27 EN 10 Circuit diagram...

Page 28: ...rts can be found in our online shop at www heylo shop de Trocknung Drying Ventilation Ventilation Luftreinigung Air cleaning Messtechnik Measurement Technology Beheizung Heating Seminare Seminars MOBI...

Reviews: