4
5
Note:
The accuracy of readout is guaranteed from 20% to 100% of
maximum range +/- 1 increment. The accuracy of the indicated
torque value is a type-bound size. For maintaining accuracy,
calibrate the wrench in regular intervals. The intervals depend
on the frequency of applications. Generally we recommend to
calibrate the torque wrench once a year.
Model Overview / Specifications
Before using the
Digital torque wrench
Model
Art . No .
Drive
Max . Reach
Accuracy
00764000080
764
1/2“
135 Nm
1 % CW / 2 % CCW
00765000080
765
1/2“
200 Nm
1 % CW / 2 % CCW
00766000080
766
1/2“
340 Nm
1 % CW / 2 % CCW
Model Overview
Model
Art .No . Drive
Max . Reach alarm setting range
(Nm)
Length
(mm)
00764000080
764
1/2“
135 Nm
6,8 - 135
410
00765000080
765
1/2“
200 Nm
10 - 200
545
00766000080
766
1/2“
340 Nm
17 - 340
640
Specifications
All models
measurement accuracy
CW +/- 1 % CCW +/- 2 %
data storage locations
50 - 250
communication
Yes
pre-settings
9 settings
Operation mode
Peak Hold / Track Mode Selection
Units
Nm, ft-Ib, in-Ib, kg-cm, Angel°
Head
Interchangeable
Bit size
12 (B) x 9 (H)
Axial distance
17,5
teeth
52
Buttons
5
Battery
2 x AA
operating temperature
-10°C - 60°C
Storage temperatur
- 20°C - 70°C
humidity
Up to 90% without condensation
Drop test
1 m
Inserting the batteries
Remove the battery cap with a rotation counterclockwise.
Insert 2 AA batteries matching the +/- polarities of the
battery to the battery compartment.
Replace the battery cap with a clockwise rotation.
Battery and cap
+
-