Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Mini prism
(GMP101)
1200
4000
1800
6000
3000
10500
Reflector tape
(GZM31)
60 mm x 60 mm
220
750
375
1200
370
1200
Machine Automa-
tion power prism
(MPR122)
1200
4000
2250
7500
3000
10500
☞
For Machine Control purposes only!
Shortest measuring distance:
1.5 m
Range
Description
A
Strong haze, visibility 5 km; or strong sunlight, severe
heat shimmer
B
Light haze, visibility about 20 km; or moderate sun-
light, slight heat shimmer
C
Overcast, no haze, visibility about 40 km; no heat
shimmer
Measurements can be made to reflector tapes over the entire range without
external ancillary optics.
Accuracy refers to measurements to standard prisms.
For TS60/TM60 - R1000:
Distance
measuring
mode
Standard
deviation
ISO 17123-4,
standard prism
Standard
deviation
ISO 17123-4,
tape**
Measurement
time, typical [s]
Precise
0.6 mm + 1
ppm*
1 mm + 1 ppm
7
Standard
1 mm + 1 ppm
1 mm + 1 ppm
2.4
Fast
2 mm + 1 ppm
3 mm + 1 ppm
2.0
Continuously
3 mm + 1 ppm
3 mm + 1 ppm
< 0.15
Averaging
1 mm + 1 ppm
1 mm + 1 ppm
-
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
*
Atmospheric conditions type C, range up to 1000 m, GPH1P reflector
**
Target aligned to instrument
For MS60 - R2000:
Atmospheric condi-
tions
☞
Accuracy
Technical Data
67
Summary of Contents for Leica Nova MS60
Page 1: ...Leica TS60 MS60 TM60 User Manual Version 4 0 English...
Page 93: ......