Replacing Synergy SAS storage solution components
Replacing HPE Synergy 12Gb SAS Connection Module
Removing the HPE Synergy 12Gb SAS Connection Module
Procedure
1. Open the release lever.
2. Remove the failed module from the frame interconnect bay.
Installing the replacement HPE Synergy 12Gb SAS Connection Module
CAUTION: Removing a module can significantly change air flow within the operating frame. Each frame bay must be
populated with a module or blanking panel for the frame to cool properly. Remove a module or blanking panel from a
frame bay only when a new module is available to install in that bay.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning
any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge.
To install the replacement SAS connection module, see "
Installing an HPE Synergy 12Gb SAS Connection Module."
Verifying proper operation
Check the following to verify that the module is working properly:
• LEDs—See
Front panel and LED definitions and check for healthy LED patterns.
• HPE OneView—View system information, status alerts, device information, and confirm that the device status is Normal.
For more information on accessing and using HPE OneView, see the online help in the product or the HPE OneView Help
for HPE Synergy in the Hewlett Packard Enterprise information library (
http://www.hpe.com/info/synergy-docs).