Technical warranty terms and conditions

At the end of this Manual you will find Guarantee Certificate containing the following warranty terms and conditions. Correctly
filled card is the basis for making a complaint regarding incorrectly working equipment.

A) It  is  prohibited  to  repair  the  unit  without  contact  with  HEWALEX  service. In  case  of  incorrect  equipment  operation,  report
failures  by  phone ((32) 214  17  10) or e-mail  ([email protected]). Depending  on  failure type,  service  team  will  be sent  to  the
site, or guidelines concerning repair of minor defects will be provided.

B) It is allowed to connect the heat pump to correctly working electrical system only. Installation requirements:

power cable to the mains socket: 3x2.5mm

2

300/500V, complying with the 227IEC53

current protection: B16 or C16

differential-current protection: 30mA

correctly made earth installation (grounding resistance should not exceed 4Ω).

All the above power supply parameters are standard and do not go beyond applicable norms.

C) Water in the system must meet the requirements specified for potable water (O.J. (Poland) no. 203, item 1718). Important for
own water intakes:

pH ranges between 6.5 and 9.5

conductivity under 2500 [uS/cm at 20°C]

ammonia under 0.5 [mg/l]

nitrates under 50 [mg/l]

chlorides content under 250 [mg/l]

copper  under  2  [mg/l,  permissible  value  provided  that  it  does  not  cause  any  change  in  water  colour  due  to  its
corrosive aggressiveness]

sulphates under 250 [mg/l]

hardness 60-500 [mg CaCO

3

]

D) Water, air and wiring systems for the unit should be made according to the guidelines and connection diagram.

E) Select proper location for the unit installation. Any damage caused by improper selection of the equipment location will not be
covered by the guarantee (that is caustic and polluted air drawn into the heat pump, unlevelled equipment, foundation tilting the
unit, installing in an unheated room).

H) It is prohibited to switch off the unit during break in operation (e.g. in wintertime). Otherwise, user will be solely responsible
for eliminating circulating pump protection against seizure and anti-freezing protection.

NOTE:

Guarantee  is  valid  since  equipment  purchase  date. Guarantee  requires  sending  the  checklist  not  later  than 30  days  after  fitting  date
(however not later than 90 days from purchase date) to the following address: HEWALEX Sp. z o.o. Sp. komandytowa, ul.Słowackiego 33,
43-502  Czechowice-Dziedzice, Poland, with  a  note: GWARANCJA  PCWU [PCWU  GUARANTEE] 2.5kW, or after  registering at

hewalex.pl/gwarancja

and filling the form.

Summary of Contents for PCWU 2.5kW

Page 1: ...the most complex controller in the HUW heat pump market in Poland possibility to control and analyse operation statistics in EKONTROL pL a separate LAN module is needed access to thoroughly metered t...

Page 2: ...Secure the unit COOLING RELATED failures Do not put your fingers inside the unit housing if it is connected to power supply There is a hazard of burning electric shock or cutting your fingers In part...

Page 3: ...tory element of power supply If user observes any alarming symptoms e g noise or odour indicating abnormal equipment operation it is required to cut off power supply and consult authorised service cen...

Page 4: ...between 6 5 and 9 5 conductivity under 2500 uS cm at 20 C ammonia under 0 5 mg l nitrates under 50 mg l chlorides content under 250 mg l copper under 2 mg l permissible value provided that it does no...

Page 5: ...nd or service works one must satisfy important for environment requirements regarding recovery reuse and utilisation of materials In particular keep to the following standards concerning cooling mediu...

Page 6: ...nt drops with decreasing air temperature and due to physical parameters of the medium in compressor system it becomes impossible to receive heat for certain low temperature of the source The same prob...

Page 7: ...the compressor in heat pump system 1 Increases cooling medium pressure and temperature to allow efficient heat transfer in heat pump condenser 2 The compressor has considerable impact on the efficien...

Page 8: ...NUOUS factory setting INTERM Solid fuel fired boiler B shown in diagrams no 5 7 9 Max boiler pump deactivation temperature 10 85 C factory setting 65 C Min boiler pump activation temperature 30 60 C f...

Page 9: ...eat pump Press arrow down to move to internal diagram of heat pump Press arrow up or wait few seconds to return to the main screen Press this button to enter individual settings menu A list of setting...

Page 10: ...llation and service instructions in the controller map Operation parameters settings After approval we may enter parameter settings screen view below on the left side Scrolling arrow down we may also...

Page 11: ...olid fuel fired boiler is working heat pump will not activate when the option of heating with solid fuel fired boiler is set Parameters of accessory equipment The second item in the list of Parameter...

Page 12: ...is too low min temperature of air supplied to the heat pump or it is switched off manually from the controller level then heater may keep heating up the tank to higher temperatures because in this ca...

Page 13: ...list is the priority of heating with solid fuel fired boiler below to the right If YES value is set and conditions required for boiler pump activation are fulfilled all other pieces of equipment opera...

Page 14: ...wish to activate the Anti Legionella function It will start on midnight Sunday Monday and keep running no longer than until 6 a m on Monday The superheating function will end earlier if temperature of...

Page 15: ...ng of inactivity time until backlight dimming the screen will get dimmed if user does not touch any keys for preset time Sounds Sound parameters allow setting keyboard sound if set to YES we will hear...

Page 16: ...Mediterranean countries however occasionally it appears in Poland as well An effective method to destroy Legionella bacteria is periodic tank superheating to water temperature reaching 70 C At this te...

Page 17: ...ipment operation statistics Another important advantage of the unit remote control is round the clock observation by the system and prompt information concerning alarms in the installation A network L...

Page 18: ...ng medium during condensation As a result of this the COP coefficient value depends not only on ambient temperature but on air humidity as well 4 Is it possible to connect the PCWU 2 5kW heat pump to...

Page 19: ...are applicable A It is prohibited to repair the unit without contact with HEWALEX service In case of incorrect equipment operation report failures by phone 32 214 17 10 or e mail serwis hewalex pl De...

Page 20: ...NO 11 Is the system provided with tested safety valve max 7 bar per HUW tank and does water flow after depressing the valve handle YES NO 12 Are suitable valves installed which would according to the...

Page 21: ...and organisational conditions which should be met by computer equipment and systems used for personal data processing O J Poland No 100 item 1024 Your personal information is kept in adequately secur...

Reviews: