Frequently asked questions regarding operation

Several issues involved in the heat pump operation have been distinguished on the basis previous questions from our clients:

1) Is  it  better  if  the  pump  works during second  (cheaper)  tariff  of  electricity  charge,  or  during  regular tariff  in  daytime,  when
outside air is warmer (provided that we take air for the pump from outside)?

There is no significant difference in operating costs, because in this case lower price of electric energy is also connected with
lower temperature of supply air at night. In case of heat pump connected to exhaust air from ventilation, in fact it is possible to
heat up the tank at lower cost overnight.

2) Is it possible to use colder exhaust air from the heat pump to cool a building?

Yes, however  in  case  of  larger  distances it  is  necessary  to use  an  additional  fan  to support  air  flow, tubes  should  be  fitted  to
ventilation system requirements and, much the same as in air-conditioners, evaporator should undergo antibacterial cleaning at
least once per year.

3) What is the condensate?

The condensate is condensed steam generated due to cooling of air flowing through the evaporator. It is a most desired effect,
because  considerable  volume  of  heat  is  transferred  to  cooling  medium during  condensation. As  a  result  of  this,  the  COP
coefficient value depends not only on ambient temperature, but on air humidity as well.

4) Is it possible to connect the PCWU 2.5kW heat pump to air conditioning station (that is work with ventilation air)?

Yes, however we should remember that the heat pump air demand reaches 350-500 m³/h. In case of work with ventilation air
the heat pump may operate all-year-round at efficiency index near 4.

5) Is it possible to unplug the unit if for example we use boiler in wintertime?

Due to the heat pump safeguards, which must be connected to power network, it is not allowed to cut off power supply of the
whole unit. In such case it is possible to switch off the heat pump from the controller level.

6) How many litres of water can be heated up within 1 hour?

A lot depends on the temperature of heated water and temperature of air drawn into the heat pump. Average volume of heated
up water ranges from 40 to 80 litres per hour.

7) Can I use this equipment to heat building?

The heat pump power has been selected so as to match utility water heating needs. We should remember that the heat pump
power drops at lower temperatures.

8) Which are minimum temperatures the PCWU 2.5kW heat pump may work at?

Minimum working temperature set at the controller is -5°C. However, its work under 0°C may result in faster wear and tear of the
compressor. Minimum working temperature should be set depending on second water heating source.

Summary of Contents for PCWU 2.5kW

Page 1: ...the most complex controller in the HUW heat pump market in Poland possibility to control and analyse operation statistics in EKONTROL pL a separate LAN module is needed access to thoroughly metered t...

Page 2: ...Secure the unit COOLING RELATED failures Do not put your fingers inside the unit housing if it is connected to power supply There is a hazard of burning electric shock or cutting your fingers In part...

Page 3: ...tory element of power supply If user observes any alarming symptoms e g noise or odour indicating abnormal equipment operation it is required to cut off power supply and consult authorised service cen...

Page 4: ...between 6 5 and 9 5 conductivity under 2500 uS cm at 20 C ammonia under 0 5 mg l nitrates under 50 mg l chlorides content under 250 mg l copper under 2 mg l permissible value provided that it does no...

Page 5: ...nd or service works one must satisfy important for environment requirements regarding recovery reuse and utilisation of materials In particular keep to the following standards concerning cooling mediu...

Page 6: ...nt drops with decreasing air temperature and due to physical parameters of the medium in compressor system it becomes impossible to receive heat for certain low temperature of the source The same prob...

Page 7: ...the compressor in heat pump system 1 Increases cooling medium pressure and temperature to allow efficient heat transfer in heat pump condenser 2 The compressor has considerable impact on the efficien...

Page 8: ...NUOUS factory setting INTERM Solid fuel fired boiler B shown in diagrams no 5 7 9 Max boiler pump deactivation temperature 10 85 C factory setting 65 C Min boiler pump activation temperature 30 60 C f...

Page 9: ...eat pump Press arrow down to move to internal diagram of heat pump Press arrow up or wait few seconds to return to the main screen Press this button to enter individual settings menu A list of setting...

Page 10: ...llation and service instructions in the controller map Operation parameters settings After approval we may enter parameter settings screen view below on the left side Scrolling arrow down we may also...

Page 11: ...olid fuel fired boiler is working heat pump will not activate when the option of heating with solid fuel fired boiler is set Parameters of accessory equipment The second item in the list of Parameter...

Page 12: ...is too low min temperature of air supplied to the heat pump or it is switched off manually from the controller level then heater may keep heating up the tank to higher temperatures because in this ca...

Page 13: ...list is the priority of heating with solid fuel fired boiler below to the right If YES value is set and conditions required for boiler pump activation are fulfilled all other pieces of equipment opera...

Page 14: ...wish to activate the Anti Legionella function It will start on midnight Sunday Monday and keep running no longer than until 6 a m on Monday The superheating function will end earlier if temperature of...

Page 15: ...ng of inactivity time until backlight dimming the screen will get dimmed if user does not touch any keys for preset time Sounds Sound parameters allow setting keyboard sound if set to YES we will hear...

Page 16: ...Mediterranean countries however occasionally it appears in Poland as well An effective method to destroy Legionella bacteria is periodic tank superheating to water temperature reaching 70 C At this te...

Page 17: ...ipment operation statistics Another important advantage of the unit remote control is round the clock observation by the system and prompt information concerning alarms in the installation A network L...

Page 18: ...ng medium during condensation As a result of this the COP coefficient value depends not only on ambient temperature but on air humidity as well 4 Is it possible to connect the PCWU 2 5kW heat pump to...

Page 19: ...are applicable A It is prohibited to repair the unit without contact with HEWALEX service In case of incorrect equipment operation report failures by phone 32 214 17 10 or e mail serwis hewalex pl De...

Page 20: ...NO 11 Is the system provided with tested safety valve max 7 bar per HUW tank and does water flow after depressing the valve handle YES NO 12 Are suitable valves installed which would according to the...

Page 21: ...and organisational conditions which should be met by computer equipment and systems used for personal data processing O J Poland No 100 item 1024 Your personal information is kept in adequately secur...

Reviews: