Measured indications
Measured indications are available from the main menu.
Here, we have one list of all temperature readings in the
system, and signals from safeguards and an external
controller. During correct operation, the LP and HP contacts
and an external control unit should be closed. Opening of
the LP and HP contacts indicates equipment failure
connected with cooling medium pressure, or pressure
controls damage.
Info
Here you will find the id. number of software used by automatics, needed in case of possible update.
5
Anti-Legionella
The type of Legionella bacteria occurs in water environment. Their growth is supported by stagnant water in the tank at the
temperature of 38-42°C. Illness, which they may develop, is called Legionellosis (type of pneumonia). Its symptoms include the
following: high fever, loss of consciousness, cough, respiratory failure. Influenza-like symptoms, diarrhoea, vomiting, bronchitis,
or fatigue and chronic respiratory disorder are also possible. Legionellosis is considered an infectious disease according to the
Ministry of Health. In case of incorrect treatment it may cause death. In majority, the disease cases are observed in
Mediterranean countries, however occasionally it appears in Poland as well.
An effective method to destroy Legionella bacteria is periodic tank superheating to water
temperature reaching 70°C. At this temperature the bacteria completely perish. The equipment
is provided with possibility to use anti-Legionella superheating every week between midnight
(Sunday/Monday) and 6 a.m. on Monday. During that time the tank is superheated to the
temperature of 70°C either by an electric heater, or e.g. gas-fired boiler, depending on the
option chosen by user (described in detail in par. ‘Operation parameters settings’, ‘Anti-
Legionella’).
If water remained in the tank unused for several days, perform an additional superheating (e.g.
after return back home).
NOTE:
Install mixing valve at the tank outlet so as to avoid burns during the Legionella superheating,
especially if water is used by small children.
According to: http://www.e-instalacje.pl/a/3244,bakterie-legionella-w-instalacjach [Joanna Ryńska, 06.12.2004]
Photos: http://www.cruiselawnews.com/tags/legionella/
6
Equipment maintenance
Detailed procedures related to the equipment maintenance are specified in installation-service part of the manual, Maintenance
chapter. User should remember about periodic checks of safety valve according to the valve manufacturer’s requirements, and
about cleaning of the filter of air drawn into the heat pump.