Technical File
File No.
ZHTF-CE-01-015
Rev. No.
A.5
Non Contact Infrared Body
Thermometer
Instructions for use
Rev. Date
2020-07-10
Page
3 / 19
3
The non contact infrared body thermometer is designed to minimize the possibility of
hazards from errors in the software program by following sound and light engineering
design processes, Risk Analysis and Software Validation.
Warning
Warnings are identified by the WARNING symbol shown above.
The Non Contact Infrared Body Thermometer is to be operated by consumers in the
home setting and primary care setting as screening tool. This manual, accessories,
Directions for Use, all precautionary information, and specifications should be read
before use.
This product is designed to measure human body temperature on the forehead. Do
not use it for any other purpose.
This product is intended in the home setting and primary care setting as screening
tool.
Do not use the thermometer if it malfunctions or has been damaged in any matter.
When the ambient temperature of the thermometer changes too much, such as
moving the Thermometer from one place of lower temperature to another place of
higher temperature, Allow the thermometer to remain in a room for 30 minutes
where the temperature is between15
to 40
(59
- 104
).
Remove primary batteries if equipment is not likely to be used for long time.
This product is not waterproof, do not be immersed in water or other liquid; If
cleaning and disinfection, please follow the "Care and Storage" section
requirements.
Do not touch the sensor of infrared detection with your fingers.
If a cold compress on the forehead fever patients, or take other measures to cool
down the temperature data will low, should be avoided in this case to measure body
temperature.
If measure human forehead temperature , please select "body" mode; for measure
other objects, liquids, food and other temperature please select "surface" mode.
This product must be operated in a stable environment, if the ambient environment
was mutations, please should be note whether there is fog on the sensor, if any,
before using accordance with the "Care and Storage" section to removing the fog.
Do not near strong electrostatic field or strong magnetic fields, thus avoiding the
impact on the accuracy of the measurement data.
Do not mix the old and new batteries to avoid damage to the product.
It may affect the accuracy of measurements when the forehead is covered by hair,
perspiration, cap or scarf.
The measuring result of this product is only for your reference. If you have any doubt,
please measure the temperature in other methods.