HE 5760 Operating Instructions
# 372449 | Version 3.2
49
Position
Bit
Function
Data type
Length (bytes)
8
Clean chamber
Digital
1
0
Chamber 1
unsigned char
to
7
Chamber 8
9
Clean chamber
Digital
1
0
Chamber 9
unsigned char
to
7
Chamber 16
10
Clean chamber
Digital
1
0
Chamber 17
unsigned char
to
7
Chamber 24
11
Clean chamber
Digital
1
0
Chamber 25
unsigned char
to
7
Chamber 32
12
Clean chamber
Digital
1
0
Chamber 33
unsigned char
to
7
Chamber 40
13
Clean chamber
Digital
1
0
Chamber 41
unsigned char
to
7
Chamber 48
14
Delta-p offset 'lower threshold
signed short
2
16
Delta-p offset 'upper threshold
signed short
2
18
Extra break 1. Control time
unsigned short
2
20
Extra break 2. Control time
unsigned short
2
22
Delta-p
signed short
2
24
System Pressure
signed short
2
25
Test command
Digital
1
1= Valve test
unsigned char
2= Chamber cleaning
3= Shut-off valve open
4= Shut-off valve closed
26
Chamber number
unsigned char
1
27
Valve number
unsigned char
1
28
reserved
1