Fault reports and their correction
76
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
Nr. Fault text
Reason
Suggestions for rectifying
180
KAS CHKDATA
Cascade parameters are not within
specification
Restart-T-Control
Check cascade parameters
181
KAS CONNECTION
No connection to cascade
Check connection to the cascade
182
KAS OFFLINE
Boiler not available for cascade
Restore data connection
189
KAS ALARM
Lead boiler could not be started or
stopped
Start lead boiler
✆
- contracting party
190
DATAERR.MEM.BOIL-MOD
Error when synchronizing boiler
extension module
✆
- contracting party
191
READY
Boiler temperature above boiler max
(90°C) boiler loaded with tom much
wood (incorrect operation); return
flow pump or return flow mixer
defective; too small buffer storage
Pufferspeicher zu klein ausgelegt
Put in less wood
Renew return flow pump or return
flow mixer
increase buffer volume
192
LIGHTING-UP
At lighting up the boiler has not
reached the flue temperature
threshold in the prescribed time
Too coarse material used
Too moist wood used;
Burner plate holes blocked
Use small wood
Use dry log wood or better quality
Clean burner plate holes
193
RE-HEATING
At re-heating the boiler has not
reached the flue temperature
threshold in the prescribed timeToo
coarse material used
Too moist wood used
Burner plate holes blocked
Use small wood
Use dry wood or better quality
Clean burner plate holes
194
EEPROM
Error at writing / reading at EEProm
Replace control
✆
- contracting party
195
STACK HZS621/622
Overflow from the stack pointer
Replace control
✆
- contracting party
196
STACK HZS631
Overflow from the stack pointer
Replace control
✆
- contracting party
12.1
Faults without text
Fault
Reason
Suggestions for rectifying
Boiler
output
gradually
decreases
Ash / slag on the grate
Fly ash container full
Heat exchangers heavily clogged/
sooted up
Reduce cleaning intervals or clean
manually.
Empty the fly ash container.
Clean the heat exchangers.
Desired operating temperature
is not reached.
Fuel of inferior quality.
Previous boiler output higher than
current boiler output
Fuel level too low
Replace fuel if necessary
Install a larger boiler
Increase fuel level
Ash is emitted from the
chimney
Fly ash container full
Fuel contains excessive fines or
super fines
Fan speeds too high
Chimney draught too high
Remove fly ash
Replace fuel if necessary or retrofit
flue gas deduster.
Reduce speeds
Retrofit chimney draught regulator
deflagrations
Fuel to dry
Fuel to fine
Use fuel according to
specifications
Summary of Contents for pelletfire
Page 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Page 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Page 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Page 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Page 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Page 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Page 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Page 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Page 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Page 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Page 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...