Description of the menu navigation and adjustment values
11
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
41
Term
Description
Unit
Overview
Fast start
Activates the fast start up (ON/OFF)
If fast start up is activated, the hot water tank is heated independently
(maximum loading time) to the requested set temperature.
-
Full loading
Activates a full loading of the hot water tank (ON/OFF)
If full-loading is activated, the hot water tank is heated up to the
requested set temperature.
(
only available, if second temperature sensor is installed)
-
Status
Hot water tank
temperature
Displays the hot water tank upper zone temperature
°C
Loading valve
Indication of the state of the loading valve
(
only visible, if hot water tank pump is activated)
-
Hot water tank pump
Indication of the state of the Hot water tank pump
(
only visible, if loading valve is inactivated)
-
Hot water tank
temperature bottom
Displays the hot water tank bottom zone temperature
(
only visible, if second temperature sensor is installted)
°C
Load-through valve
Indicates the state of the load-through valve
(
only visible, if load-through valve is activated and a heat pump is
installed)
-
Circulation temperature
Indicates the circulation temperature
(
only visible, if circulation pump is activated)
°C
Circulation pump
Indicates the state of the circulation pump
(
only visible, if circulation pump is activated)
-
Settings
Must-temperature
Setting up the hot water tank set temperature (50-85).
°C
Min.loading /
temperature
Indicates/activates the min. loading / temperature (20-55) (ON/OFF)
If the hot water tank min. loading / temperature is activated and the
state out of max loading time, the hot water tank temperature will be set
equal to min. loading / temperature.
If hot water tank temperature is lower than the min. loading /
temperature value, the hot water tank loading will start
°C
Temp.increase
Setting up an increase (0-15) of the required hot water tank temperature
Compensates heat loss by exceeding the hot water tank set
temperature
°C
Max. loading time
Setting up maximum hot water tank loading time (0-10), when hot water
tank is loaded up to hot water tank set temperature
h
Legio temperature
Setting up the legionella temperature (0-95)
Hot water tank will be heated up, within the given hot water tank
loading time, to the legionella temperature weekly to kill bacteria
A deactivation of this parameter is done by setting up the legionella
temperature to 0 °C.
°C
MODUL
Boiler
Buffer
Hot water tank
Heating circuit
Time mode
Solar
Hydr.compensat
Net pump
Zone valve
Ext. requirement
addit. boiler
Summary of Contents for pelletfire
Page 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Page 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Page 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Page 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Page 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Page 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Page 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Page 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Page 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Page 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Page 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...