Description of the menu navigation and adjustment values
11
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
53
Term
Description
Unit
Status
Hydr. compensator
temperature
Display of the temperature in the hydr. compensator
In the hydr. compensator is a temperature sensor which measures
the temperature in the hydr. compensator
°C
Existing temperature
Display of the flow temperature of the preceding module (e.g. boiler,
buffer)
°C
Required temperature
Display of the required temperature of the downstream module (e.g.
heating circuit)
°C
Pump 1
Indication of the state of pump 1 (ON/OFF)
Pump 1 is the pump in the back flow on the primary side
-
Pump 2
Indication of the state of pump 2 (ON/OFF)
Pump 2 is the pump in the flow on the secondary side
-
Settings
Switch on barrier
Setting the switch on barrier for pump 2:
Is the flow temperature of the preceding module (e.g. boiler, buffer)
higher than the adjusted switch on barrier, pump 2 is switched on. Is
this not the case, pump 2 stays switched off.
°C
Temp.increase
Adjusting the temperature increase for the required temperature
Due to heat losses you can adjust an addition to the required
temperature of the downstream module
°C
Agg-Test
Pump 1*
Indication of the state of pump 1:
Pump 1 is the pump in the back flow on the primary side
When the indicator lamp lights up pump 1 is switched on
-
Pump 2*
Indication of the state of pump 2:
Pump 2 is the pump in the flow on the secondary side
When the indicator lamp lights up pump 2 is switched on
-
MODUL
Boiler
Buffer
Hot water tank
Heating circuit
Time mode
Solar
Hydr.compensat
Net pump
Zone valve
Ext. requirement
addit. boiler
Summary of Contents for pelletfire
Page 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Page 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Page 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Page 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Page 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Page 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Page 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Page 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Page 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Page 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Page 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...